PRO SIGNAL PSG04175 Manual Download Page 5

better. The leftward arrow means that the air pressure is decreasing and the weather is expected to 
become worse. 

The change of weather forecast icon is in accord to the relationship between current relative pressure and 
the pressure change since last six hours. If the weather is changing, weather tendency indicator (animated 
arrows) will be flashing for three hours indicating a weather change is happening. After that, if weather 
conditions have become stable and no new weather change condition met, then the arrows will be fixed.     

4.4 Examples of changing weather icons: 

4.5 Storm warning indicator 

The storm threshold can be set 

to suit the user’s requirement for storm forecasting from 3-9hPa (default 

4hPa). When there is a fall over pressure threshold within 3 hours, the storm forecasting will be activated, 
the clouds with rain icon and tendency arrows will flash for 3 hours indicating the storm warning feature has 
been activated. 

Notes to pressure sensitivity setting for weather forecasting: 

 

The pressure threshold can be set to sui

t the user’s requirement for weather forecasting from 2-4hPa 

(default 2hPa). For areas that experience frequent changes in air pressure requires a higher setting 
compared to an area where the air pressure is stagnant. For example, if 4hPa is selected, then there must 
be a fall or rise in air pressure of at least 4hPa before the weather station will register this as a change in 
weather.   

5. Program Mode

The  base  station  has  five  keys  for  easy  operation: 

SET

  key, 

ALARM

  key,

  MIN/MAX

  key 

+

  key  and

SNOOZE/LIGHT

 key. And there are four program modes available: Quick Display Mode, Setting Mode,

Alarm Mode and Min/Max Mode.

The program mode can be exited at any time by either pressing the 

SNOOZE/LIGHT

 key, or waiting for 

the 10-second time-out to take effect. 

5.1 Quick Display Mode 

- While in Normal Mode, press the 

SET

 key to enter the Quick Display Mode as follow:

1.

Outdoor  Temperature  /  Dew  point  (press  the 

MIN/MAX

  key  or 

+

  key  shifts  the  display  between

outdoor temperature and dew point)

2.

Absolute pressure / Relative pressure (press the 

MIN/MAX

 key or 

+

 key shifts the display between

the absolute pressure and relative pressure)

- press the 

SET

 key to accept the change and advance to the next display mode. Continues to press the

SET

 key to toggle through the display mode until return to the normal Mode

5.2 Setting Modes 

1.

Press the 

SET

 key for 3 second while in normal mode to enter the normal Setting mode

2.

Press the 

SET

 key to select the following setting  in sequence:

1)

12/24-hour format

2)

Manual time setting (hours/minutes)

Summary of Contents for PSG04175

Page 1: ...d should be kept in a safe place for future reference It contains important notes on setup and operation 2 2 2 2 4 5 5 5 5 5 6 7 8 8 3 3 3 4 7 y Do not expose the main unit to rain or moisture y Use o...

Page 2: ...ll pick up the signal from the transmitter To measure outdoor temperature place the transmitter outdoors It will transmit the temperature from its location Every time the remote sensor is powered up f...

Page 3: ...educe the range If a north facing wall is not possible choose a shaded area under an eve 1 Use a screw or nail to affix the remote sensor to the wall 2 Hang the remote sensor up using string or a zip...

Page 4: ...ure display 22 General outdoor alarm icon 23 Weather tendency indicator 24 Barometer air pressure 25 Pressure display unit inHg or hPa 26 Pressure alarm on indicator 4 2 Weather forecasting Sunny Part...

Page 5: ...uires a higher setting compared to an area where the air pressure is stagnant For example if 4hPa is selected then there must be a fall or rise in air pressure of at least 4hPa before the weather stat...

Page 6: ...particular alarm will sound and flash for 120 second Press any key to mute the alarm When weather alarm condition was activated again within 10 minutes alarm will not sound but will continue to flash...

Page 7: ...aximum value will be reset to current reading 1 Indoor humidity maximum 2 Indoor temperature maximum 3 Outdoor humidity maximum 4 Outdoor temperature maximum 5 Outdoor dewpoint maximum 6 Pressure maxi...

Page 8: ...ield Frequency Temperature range Resolution Measuring range rel humidity Humidity accuracy 100meter max 433MHz 40 to 60 displays OFL if outside range 0 1 20 95 5 within 0 45 48 sec IPX3 48 sec 0 to 60...