background image

The following items are included in the package.  Before using, please ensure every-
thing is there.

This unit has been carefully packed, with special attention to quality.  However, should
you find anything damaged or missing, please contact your local GP distributor im-
mediately.

Package Contents

Manual

GP477R/577R Series

User’s Manual

Extra-Cost Options

Cables

Adapters

Screen editor software

are optionally available.

For more information, see Digital's cata-
logues.

GP unit

(GP477R-EG41-24VP)

Handling guide 1 sheet

(this sheet)

Installation fasteners (4 pcs)

Handling

Guide

Digital

GP477R/577R Series

User's Manual

Summary of Contents for GP477R-EG41-24VP

Page 1: ...t or press the touch panel with too much force for it may cause irreparable damage Do not use GP in an environment where the surrounding temperature exceeds the specification range for it may damage t...

Page 2: ...earth terminal Be sure to connect this terminal in accordance with UL standards Installation and operation instructions are provided with each GP These installation instructions contain the following...

Page 3: ...g damaged or missing please contact your local GP distributor im mediately Package Contents Manual GP477R 577R Series User sManual Extra Cost Options Cables Adapters Screen editor software are optiona...

Page 4: ...d terminals for AC power cable E Auxiliary Input Output AUX Operates the Touch Switch System Alarm Buzzer Run outputs and Remote Reset inputs F Serial Interface RS 232C RS 422 Serial interface Connect...

Page 5: ...minal If necessary you may also need to connect the FG terminal to the other unit s FG terminal depending on the type of the other unit you use Pin Signal Name Condition Pin Signal Name Condition 1 FG...

Page 6: ...PDB2 5 PDB3 6 PDB4 7 PDB5 8 PDB6 9 PDB7 10 1 INIT 11 BUSY 12 NC 13 NC 14 GND When making a cable please be aware of the following For RS 422 Connection The following pairs of pin s must be connected...

Page 7: ...over XM2S 1511 madebyOMRONCorp JackScrew XM2Z 0071 madebyOMRONCorp Use rough metric type M2 6 x 0 45p threads used to hold the cable s set fastening screws in place 5 AUX Interface Input Output Pin Co...

Page 8: ...screws with too much force can cause a damage Panel GPunit 1 0 1 0 Before installing the GP into a cabinet or panel check that the Installa tion gasket is securely attached to the unit Confirm the Ins...

Page 9: ...inals with a sleeve 7 Wiring To avoid electric shock be sure the Power Cable is unplugged from the power outlet when connecting the cable to the GP unit GP477R EG41 24VP can only take DC24V input If y...

Page 10: ...N m Please pay special attention to the following instructions when connecting the power cable to the GP unit If the supply voltage exceeds the GP unit range connect a voltage transformer For between...

Reviews: