locate the blower switch inside the main cabin and press the switch to the on position. Then, go back to
the bilge area and listen to hear if the blower is running. The exhaust vents are located on the outside of
the transom on the port and starboard sides. Check to ensure that air is blowing out of the vents. When
finished, go back into the cabin and turn the blower switch off.
Blower
Blower switch
Blower exhaust vent
Generator (Gas) 5.0 kw w/Carbon Monoxide Detector and Auto Shut Off (Optional)
If you have selected the optional generator, your vessel will come equipped with a remote start/stop for
the generator, carbon monoxide detectors with auto shut off controls, an hour meter and a blower switch.
WARNING: The switch for the blower is installed next to the AC/DC panel and should be
turned on for four (4) minutes prior to starting your engines or the generator to ensure
that the bilge is free from any gas fumes. The blower vents are located on the inside
wings of the Euro transom/dive platform.
The generator is installed in the aft area of the bilge and it can be started either direct from the generator
or remotely from the AC Panel in the cabin.
Note: The manufacturer of the generator provides the limited warranty for the generator
and most associated parts. Please refer to their owner’s manual and follow their
recommendations for scheduled maintenance and service. To be in accordance with the
terms and conditions of their limited warranty, all service and/or warranty repairs
must
be
performed by a repair facility that is authorized to work on their equipment.
Generator
Generator
seacock lever is in
the closed
Before attempting to operate the generator, the boat must be in the water and/or have some type of water
flushing system going into the generator water pick up. The generator seacock is mounted on the port
side in the bilge. Inspect the seacock and ensure that it is open and that the hoses are all connected.
23