background image

16

HOW TO PLUG IN THE POWER CORD ON THE
LIGHT THERAPY POD

This product must be grounded. 

If it should mal-

function or break down, grounding provides a path of
least resistance for electric current to reduce the risk
of electric shock. This product is equipped with a cord
having an equipment-grounding conductor and a
grounding plug. 

Plug the power cord into an appro-

priate outlet that is properly installed and ground-
ed in accordance with all local codes and ordi-
nances.

This product is for use on a nominal 120-volt circuit,
and has a grounding plug that looks like the plug 
illustrated in drawing 1 below. A temporary adapter
that looks like the adapter illustrated in drawing 2 may
be used to connect the power cord to a 2-pole recep-
tacle as shown in drawing 2 if a properly grounded
outlet is not available. 

The temporary adapter should be used only until a
properly grounded outlet (drawing 1) can be installed
by a qualified electrician. 

The green-colored rigid ear, lug, or the like extending
from the adapter must be connected to a permanent
ground such as a properly grounded outlet box cover.
Whenever the adapter is used it must be held in place
by a metal screw. 

Some 2-pole receptacle outlet box

covers are not grounded. Contact a qualified 
electrician to determine if the outlet box cover is
grounded before using an adapter.

HOW TO USE THE LIGHT THERAPY POD

The light therapy
pod allows you
to enjoy the ben-
efits of light ther-
apy while you
exercise or while
you simply relax. 

The effective-
ness of light ther-
apy depends on
two factors: your
distance from the
light and the length of time you use the light. The chart
below shows the intensity of the lights at different dis-
tances.

Light

Therapy

Pod

DANGER:

Improper connection

of the equipment-grounding conductor can
result in an increased risk of electric shock.
Check with a qualified electrician or service
representative if you are in doubt as to
whether the product is properly grounded. Do
not modify the plug provided with the prod-
uctÑif it will not fit the outlet, have a proper
outlet installed by a qualified electrician.

1

Grounded Outlet Box

Light Cycle

Power Cord

Grounding Plug

Grounding Pin

Grounded Outlet

2

Grounded Outlet Box

Adapter

Lug

Metal Screw

Grounding Pin

Grounding Plug

Distance

12Ó

18Ó

24Ó

Lux

10,000

3,200

2,500

1,500

WARNING: Before beginning this or any light
therapy program, consult your physician.

WARNING: The light therapy pod becomes
hot during use. Allow the light therapy pod
to cool before touching it.

Summary of Contents for Light Cycle PFRX35390

Page 1: ...there are missing parts we will guar antee complete satisfaction through direct assistance from our factory TO AVOID UNNECESSARY DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The train...

Page 2: ...D WARRANTY Back Cover CAUTION DECAL PLACEMENT The decals shown below have been placed on the Light Cycle If one of the decals is missing or if it is not legible please call our Customer Service Depart...

Page 3: ...he power cord away from heated surfaces 12 If you have serious back injuries or chronic back pain consult a physician before using the lumbar cushion 13 Do not use the lumbar cushion if you are pregna...

Page 4: ...Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please mention the product model number and serial number when calling The model number is PFRX35390 The serial number c...

Page 5: ...wing refers to the key number of the part from the part list on page 12 The second number refers to the quantity used in assembly Note Some small parts may have been pre attached for shipping If a par...

Page 6: ...ut do not tighten the Screws yet Make sure that the Screws are in the indicated holes Note Two more Screws will be attached in step 6 Remove the backing from the Fastener Strip 77 and press it onto th...

Page 7: ...e 3 with four M10 x 105mm Button Head Bolts 70 four M10 Flat Washers 71 and four M10 Nylon Locknuts 72 8 Attach the Seat 16 to the Seat Bracket 69 with four M6 x 16mm Hex Head Screws 24 71 71 69 69 3...

Page 8: ...Right Pedal not shown clock wise into the right arm of the Crank 29 Adjust the Pedal Strap 27 on the Left Pedal 45 to the desired position Press the Pedal Strap onto the tab on the Left Pedal Adjust t...

Page 9: ...negative ends of the bat teries are turned away from the motor Close the zipper 14 Slide the Lumbar Cushion 94 over the Backrest 15 as shown 94 Zipper Battery Clip Motor Batteries 15 94 Elastic Strap...

Page 10: ...rn the Resistance Knob counterclockwise HOW TO USE THE LUMBAR CUSHION Slide the Lumbar Cushion 94 over the Backrest 15 as shown Adjust the position of the Lumbar Cushion until it feels comfortable aga...

Page 11: ...on the left side of the console show how the target pace will change during each program see the drawing above Each graph is divided into ten columns and each column represents 1 10 of a mile The bar...

Page 12: ...f you selected a pacer program two indicators on the P A C E R track will light The indicator on the inner track will show your actual pace The indicator on the outer track will move around the track...

Page 13: ...lace by a metal screw Some 2 pole receptacle outlet box covers are not grounded Contact a qualified electrician to determine if the outlet box cover is grounded before using an adapter HOW TO USE THE...

Page 14: ...d the metal contacts your muscle movement may interfere with heart rate readings For the most accurate heart rate reading wait for about 15 seconds For optimal performance of the pulse sensor keep the...

Page 15: ...Place the end of a standard screw driver in one of the slots in the slotted bearing nut Lightly tap the screwdriver with a hammer to turn the slotted bearing nut counterclockwise until the arms are n...

Page 16: ...n you stop exercising If your heart rate is too high decrease the intensity of your exer cise If your heart rate is too low increase the intensity of your exercise WORKOUT GUIDELINES A well rounded wo...

Page 17: ...spect to any economic loss loss of property loss of revenues or profits loss of enjoyment or use costs of removal installation or other consequential damages of whatsoever nature Some states do not al...

Page 18: ...0 1 Cable Clamp 51 1 M6 x 56mm Bolt 52 2 M8 Split Washer 53 4 8 Flat Washer 54 1 Clamp Bolt 55 1 Clamp Nut 56 1 Resistance Hook 57 1 Resistance Spring 58 1 Magnet Bracket 59 1 M8 x 65mm Hex Head Bolt...

Reviews: