13

To avoid personal injury, always shut off and 

unplug the compressor and relieve all air pressure from 
the system before performing any service on the air 
compressor.

Regular maintenance will ensure trouble free operation.

Your electric powered air compressor represents high quality
engineering and construction; however, even high quality
machinery requires periodic maintenance. The items listed
below should be inspected on a regular basis.

Condensation will accumulate in the 

tank. To prevent corrosion of the tank from the inside, 
this moisture must be drained at the end of every 
workday. Be sure to wear protective eyewear. Relieve 
the air pressure in the system and open the drain valve
on the bottom of the tank and tilt tank to drain.

NOTE:

In cold climates, drain the tank after each use to 
reduce problems with freezing of water 
condensation.

WARNING:

WARNING:

MAINTENANCE

MAINTENANCE

DRAINING THE TANK

B

OPEN

D

CLOSE

Summary of Contents for VPF1080318

Page 1: ...nstructions in this manual could result in personal injury property damage and or voiding of your warranty The manufacturer WILL NOT be liable for any damage because of failure to follow these instruc...

Page 2: ...S 8 ELECTRICAL POWER REQUIREMENTS 9 Electrical Wiring 9 Extension Cords 9 Grounding Instructions 9 OPERATING INSTRUCTIONS 11 Daily Startup 11 Shutdown 11 MAINTENANCE 13 16 Draining the Tank 13 Checkin...

Page 3: ...ll protect you 8 RISK OF EYE INJURY Always wear ANSI Z87 1 approved safety goggles when using an air compressor Never point any nozzle or sprayer toward a person or any part of the body Equipment can...

Page 4: ...l shut it down to prevent damage to the motor When the motor sufficiently cools it will automatically reset The pump see A compresses the air and discharges it into the tank The tank see B stores the...

Page 5: ...Position the compressor near a grounded electrical outlet see GROUNDING INSTRUCTIONS page 9 Avoid using an extension cord use a longer hose instead b The compressor must be at least 12 inches 31 cm fr...

Page 6: ...To operate manually pull the ring on the valve to relieve air pressure in the tank Tank Pressure Gauge see C This gauge measures the pressure level of the air stored in the tank It is not adjustable b...

Page 7: ...ct is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes...

Page 8: ...ch the desired pressure Do not exceed operating pressure of the tool or accessory being used 5 If a pressure regulator is present on your compressor adjust it to the working pressure of the tool 1 Tur...

Page 9: ...res periodic maintenance The items listed below should be inspected on a regular basis Condensation will accumulate in the tank To prevent corrosion of the tank from the inside this moisture must be d...

Page 10: ...200 2705 14 PARTS LIST 040 0418 U2C Pump Breakdown ITEM 61 ITEM 60 ITEM 59...

Page 11: ...x 1 x 30mm 32 N A 4 Washer Lock m6 33 042 0128 1 Head 34 Order item 60 1 Gasket Cylinder Head 35 Order item 60 1 Valve Plate assembly 36 Order item 60 2 Reed Valve 37 Order item 60 1 Gasket Valve Plat...

Page 12: ...f bubbles appear repair or replace the faulty component Do not overtighten any connections Before storing the compressor for a prolonged period use an air blow gun to clean all dust and debris from th...

Page 13: ...auge reading drops when air accessory is being used PROBLEM WARNING Replace pressure switch Tank pressure exceeded normal operating pressure Replace pressure switch Pressure switch stuck Motor will st...

Page 14: ...ord the model number serial number and date purchased in the spaces provided below Retain your sales receipt and this manual for future reference When needing service please contact the nearest author...