background image

200-2705

17

Note:  Troubleshooting problems may have similar causes and solutions.

Close drain valve

Tank drain valve is open

Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.

Fittings Leak

Clean or replace air filter element.

Restricted air intake

Decrease amount of air used.

Prolonged excessive use of air

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor. 
Most accessories are rated at 25% of actual CFM while running
continuously.

Compressor not large enough

Check and replace if necessary.

Hole in air hose

Immediately replace tank. DO NOT attempt to
repair.

Tank leaks

Replace compressor assembly.

Valve leaks

Replace compressor assembly.

Leaking or worn piston

Replace compressor assembly.

Blown seals

Replace regulator or internal parts.

Dirty or damaged regulator
internal parts.

If pressure drops too low, adjust regulator while accessory is used.

This is normal

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Compressor not large enough

SOLUTION

POSSIBLE CAUSE

Low pressure or not
enough air
or 
Compressor does not
stop

Air leaks from regulator,
or regulator does not
regulate pressure

Regulated pressure
gauge reading drops
when air accessory is
being used

PROBLEM

WARNING

:

Replace pressure switch

Tank pressure exceeded normal
operating pressure

Replace pressure switch

Pressure switch stuck

Motor will start automatically when tank pressure drops below 
kick-in pressure of pressure tank.

Tank pressure exceeds preset
pressure switch limit

Let motor cool off and overload switch will automatically reset. This
may take several minutes.

Motor overload protection has
tripped

• Replace blown fuse or resed circuit breaker. Do not use fuse or

circuit breaker with higher rating than specified for your branch
circuit.

Fuse blown or circuit breaker
tripped

• Check for proper fuse; “Fusetron” type T is acceptable.

• Check for low voltage and proper extension cord size.

• Disconnect other applications from circuit. Operate compressor

on a dedicated circuit.

Remove and clean or replace.

Check valve stuck open

Bleed line by moving pressure switch lever to OFF Position before
restarting. If bleeder valve does not open, replace bleeder valve.

Pressure bleeder valve on
pressure switch has not
unloaded head pressure

Check for proper gauge and extension cord length.

Wrong wire gauge in cord or
excessive extension cord length

Contact authorized service center.

Loose electrical connections

Contact authorized service center.

Possible defective capacitor

Have checked at service center. Do not operate compressor in the
paint spray area

Paint spray on internal motor
parts

Have checked at service center.

Possible defective motor

Pressure relief valve
opens

Motor will not run

TROUBLESHOOTING CHART

Summary of Contents for VPF1080318

Page 1: ...nstructions in this manual could result in personal injury property damage and or voiding of your warranty The manufacturer WILL NOT be liable for any damage because of failure to follow these instruc...

Page 2: ...S 8 ELECTRICAL POWER REQUIREMENTS 9 Electrical Wiring 9 Extension Cords 9 Grounding Instructions 9 OPERATING INSTRUCTIONS 11 Daily Startup 11 Shutdown 11 MAINTENANCE 13 16 Draining the Tank 13 Checkin...

Page 3: ...ll protect you 8 RISK OF EYE INJURY Always wear ANSI Z87 1 approved safety goggles when using an air compressor Never point any nozzle or sprayer toward a person or any part of the body Equipment can...

Page 4: ...l shut it down to prevent damage to the motor When the motor sufficiently cools it will automatically reset The pump see A compresses the air and discharges it into the tank The tank see B stores the...

Page 5: ...Position the compressor near a grounded electrical outlet see GROUNDING INSTRUCTIONS page 9 Avoid using an extension cord use a longer hose instead b The compressor must be at least 12 inches 31 cm fr...

Page 6: ...To operate manually pull the ring on the valve to relieve air pressure in the tank Tank Pressure Gauge see C This gauge measures the pressure level of the air stored in the tank It is not adjustable b...

Page 7: ...ct is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes...

Page 8: ...ch the desired pressure Do not exceed operating pressure of the tool or accessory being used 5 If a pressure regulator is present on your compressor adjust it to the working pressure of the tool 1 Tur...

Page 9: ...res periodic maintenance The items listed below should be inspected on a regular basis Condensation will accumulate in the tank To prevent corrosion of the tank from the inside this moisture must be d...

Page 10: ...200 2705 14 PARTS LIST 040 0418 U2C Pump Breakdown ITEM 61 ITEM 60 ITEM 59...

Page 11: ...x 1 x 30mm 32 N A 4 Washer Lock m6 33 042 0128 1 Head 34 Order item 60 1 Gasket Cylinder Head 35 Order item 60 1 Valve Plate assembly 36 Order item 60 2 Reed Valve 37 Order item 60 1 Gasket Valve Plat...

Page 12: ...f bubbles appear repair or replace the faulty component Do not overtighten any connections Before storing the compressor for a prolonged period use an air blow gun to clean all dust and debris from th...

Page 13: ...auge reading drops when air accessory is being used PROBLEM WARNING Replace pressure switch Tank pressure exceeded normal operating pressure Replace pressure switch Pressure switch stuck Motor will st...

Page 14: ...ord the model number serial number and date purchased in the spaces provided below Retain your sales receipt and this manual for future reference When needing service please contact the nearest author...

Reviews: