200-2705
8
ON/OFF Switch
(see
A
)
This switch turns on the compressor. It is operated
manually, but when in the ON position, it allows the compressor
to start up or shut down automatically, without warning, upon
air demand. ALWAYS set this switch to OFF when the
compressor is not being used, and before unplugging the
compressor.
Pressure Relief Valve
(see
B
)
If the pressure switch does
not
shut down the motor when
pressure reaches the preset level, this valve will pop open
automatically to prevent over pressurization. To operate
manually, pull the ring on the valve to relieve air pressure in the
tank.
Tank Pressure Gauge
(see
C
)
This gauge measures the pressure level of the air stored in
the tank. It is not adjustable by the operator, and does
not
indicate line pressure.
Air Pressure Regulator
(see
D
)
This air pressure regulator enables you to adjust line
pressure to the tool you are using.
Never exceed the maximum working
pressure of the tool.
Turn the knob clockwise to increase pressure, and
counterclockwise to decrease pressure.
Regulated pressure gauge
(see
E
)
This gauge measures the regulated outlet pressure.
Air line outlet
(see
F
)
Connect an air hose to this outlet.
WARNING:
COMPRESSOR CONTROLS
COMPRESSOR CONTROLS
E
A
F
C
B