UL/c-UL(CSA) Approval

CE Marking

The GLC2300-LG41-24V/GLC2300-TC41-24V units are UL/c-UL(CSA) recog-
nized components. UL file no. E231702 (UL1604)

When applying for UL approval for a product that includes one of these GLC units,
please be sure to pay special attention to the fact that all products with built-in GLC
units require UL inspection of the combination of the GLC and the product.

The GLC components conform to the following standards:

- UL1604 and UL60950 Third Edition

Safety of Information Technology Equipment for use in Class I and II, Division 2,
and Class III Hazardous (classified) locations.

- CAN/CSA-C22.2 No.60950-00 and No.213-M1987

Safety of Information Technology Equipment for use in Class I and II, Division 2,
and Class III Hazardous (classified) locations.

GLC2300-LG41-24V (UL Registration Model: 2980070-11)

GLC2300-TC41-24V (UL Registration Model: 2980070-12)

Installation Precautions

If the GLC is mounted so as to cool itself naturally, please mount it on a vertical
panel.  Also, insure that the GLC is mounted at least 100 mm away from any other
adjacent structures or machine parts.  If these conditions are not met, the heat gener-
ated by the GLC's internal components may cause it to fail to meet UL standards.

UL1604 - Compliance and Handling Cautions

1. Power and input/output wiring must be in accordance with Class I, Division 2

wiring methods - Article 501-4(b) of the National Electrical Code, NFPA 70
within the United States, and in accordance with Section 18-152 of the Canadian
Electrical Code for units installed within Canada.

2. Suitable for use in Class I, Division 2, Groups A, B, C, and D Hazardous Loca-

tions.

3. WARNING: Explosion hazard

- substitution of components may impair com-

pliance to Class I, Division 2.

4. WARNING: Explosion hazard

- when in hazardous locations, turn the power

OFF before replacing or wiring modules.

5. WARNING: Explosion hazard

- confirm that the power supply has been turned

OFF before disconnecting equipment, or
confirm that the location is not subject to the
risk of explosion.

The GLC2300-LG41-24V/GLC2300-TC41-24V units are CE marked, EMC compliant
products.  These units also conform to EN55011 Class A, EN61000-6-2 directives. For
detailed CE marking information, please contact your local GLC distributor.

Summary of Contents for GLC2300-LG41-24V

Page 1: ...ident can occur To prevent this be sure to set up external watchdog circuits that will monitor vital output signals Be sure to design a circuit that will supply power to the GLC s I O unit before star...

Page 2: ...fety and reliability When using the GLC with transportation vehicles trains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical devi...

Page 3: ...rm that the GLC s power cord is unplugged before either cleaning the GLC or at taching detaching the power terminal block screws When replacing the GLC s backlight be sure to unplug the unit s power c...

Page 4: ...e a fire accident or malfunction GLC Operation and Maintenance Cautions Be sure to read the GLC s manual and on line help information carefully before performing program changes forced output or utili...

Page 5: ...mounted at least 100 mm away from any other adjacent structures or machine parts If these conditions are not met the heat gener ated by the GLC s internal components may cause it to fail to meet UL st...

Page 6: ...en carefully packed with special attention to quality However should you find anything damaged or missing please contact your local GLC distributor immediately GLC Unit 1 GLC2300 LG41 24V GLC2300 TC41...

Page 7: ...am features 3 Changing to OFFLINE will release and stop ladder circuit program features Front Rear Bottom D Power Input Terminal Block E Expansion Unit Interface F CF Card Access LED G Serial Interfac...

Page 8: ...CF Card is disabled CF Card with startup data required 2 Reserved Always OFF 3 Reserved Always OFF 4 This setting controls the forced closing of the CF Card cover Forced close enabled Forced close di...

Page 9: ...ctor Dsub25 pinplugXM2A 2501 madebyOMRONCorp RecommendedCover Dsub25 pinCoverXM2S 2511 madebyOMRONCorp RecommendedCover Dsub25 pinCoverXM2S 2521 madebyOMRONCorp RecommendedScrew JackScrewXM2Z 0071 mad...

Page 10: ...ector Pin Arrangement Pin Signal Name Description 1 CD Carrier Detect RS 232C 2 RD Receive Data RS 232C 3 SD Send Data RS 232C 4 ER Enable Receive RS 232C 5 SG Signal Ground 6 DR Data Set Ready RS 232...

Page 11: ...is securely attached to the unit A gasket which has been used for a long period of time may have scratches or dirt on it and could have lost much of its dust and drip resistance Be sure to change the...

Page 12: ...ghten it with a screwdriver Installation fastener Panel GLC Insertion Slots Insertion Slots Top Bottom Tightening the screws with too much force can damage the GP s plastic case The necessary torque i...

Page 13: ...a screwdriver to remove the Power Input Terminal Block s clear plastic cover 3 Unscrew the screws from the middle three 3 terminals align the Ring Terminals and re attach the screws 4 Replace the Pow...

Page 14: ...main circuit lines high voltage high current or input output signal lines Connect a surge absorber to handle power surges To reduce noise make the power cord as short as possible Depending on the inpu...

Reviews: