Specifications
44
NOTE:
1. The above table lists the non-incendive circuit parameters. The Entity Concept allows intercon-
nection of non-incendive apparatus with associated apparatus – not specifically examined
combinations – as a system when the approved values of V
oc
(or U
o
) and I
sc
(or I
o
) for the
associated apparatus are less than or equal to V
max
(U
i
) and I
max
(I
i
) for the non-incendive
apparatus, and the approved values of C
a
(C
o
) and L
a
(L
o
) for the associated apparatus are greater
than or equal to C
i
+ C
cable
and L
i
+ L
cable
, respectively, for the non-incendive field wiring
apparatus.
2. Associated non-incendive field wiring apparatus and non-incendive field wiring apparatus shall
satisfy the following:
3. If the electrical parameters of the cable are unknown, the following values may be used:
C
cable
= 196.85 pF/m (60 pF/ft)
L
cable
= 0.656
H/m (0.20
H/ft)
4. Wiring methods must be in accordance with the electrical code of the country where it is used.
This product must be installed in an enclosure. If installed in a Class I, Division 2 Location, the
enclosure must be capable of accepting one or more Division 2 wiring methods.
Associated non-incendive
field wiring apparatus
-
Non-incendive field wiring
apparatus
V
oc
V
max
I
sc
I
max
C
a
C
i
+ C
cable
L
a
L
i
+ L
cable
DANGER
POTENTIAL FOR EXPLOSION
Verify the power, input, and output (I/O) wiring are in accordance with Class I, Division 2 wiring
methods.
Substitution of any components may impair suitability for Class I, Division 2.
Do not disconnect equipment while the circuit is live or unless the area is known to be free of
ignitable concentrations.
Remove power before attaching or detaching any connectors to or from this product.
Ensure that power, communication, and accessory connections do not place excessive stress
on the ports. Consider the vibration in the environment when making this determination.
Securely attach power, communication, and external accessory cables to the panel or cabinet.
Use either a USB cable by Pro-face or a commercial-type USB cable.
Use only non-incendive USB configurations.
The associated non-incendive field wiring apparatus shall not be connected in parallel unless
approved by the associated non-incendive apparatus.
This product is suitable for use and provides non-incendive field wiring to apparatus in Class
I, Division 2, Groups A, B, C, D.
Failure to follow these instructions will result in death or serious injury.
Summary of Contents for FP5000 Series
Page 1: ...FP5000 Series User Manual FP5000 MM01 EN PDF_02...
Page 6: ...6...
Page 10: ...10...
Page 22: ...Overview 22 KC Markings...
Page 26: ...Device Connectivity 26...
Page 30: ...Parts Identification and Functions 30...
Page 48: ...Dimensions 48 FP 5600TPD External Dimensions 1 Front 2 Left 3 Bottom...
Page 50: ...Dimensions 50 FP 5700TPD External Dimensions 1 Front 2 Left 3 Bottom...
Page 52: ...Dimensions 52...
Page 72: ...Installation and Wiring 72...