3.

WARRANTY WILL BE VOID IF ANY COMPONENTS OR ACCESS COVERS ARE 

REMOVED FROM THE INTELLI-TORK DEVICE.

INTRODUCTION INTELLI-TORK CLOUD USER MANUAL

(Note: The information provided within this document is applicable to all Intelli-Tork Cloud Systems.)

There is no power button on the Intelli-Tork hub. Once the user disconnects from the hub, 

it will enter sleep mode awaiting connection. Operators must ensure proper disconnection 

from the hub to maintain maximum battery life. 

The battery life of this system has been designed to exceed 10.5 month of usage running 10 

hours a day, 5 days a week in -20° F. Battery replacement will occur automatically during your 

yearly calibration.

Communication range for the Intelli-Tork System is 300’ line of sight. Note that obstructions 

may diminish the communication range.

Intelli-Tork Hub Operating Temperature Range: -30° F to 130°F

The Intelli-Tork hub has been tested to 12’ submersion depth for 24 hours.  At no time should 

the hub be subjected to pressurized wash down.  The hub should be cleaned with water and 

mild detergent as required.

Summary of Contents for Intelli-Tork H200

Page 1: ...al Owners Manual Safety Precautions Manual number PROITK Release Date June 2021 Operating Instructions Maintenance Parts Lists 785 856 2661 WWW PRO DIG USA COM WIRELES SCREW PIER TORQUE MONITORING SYS...

Page 2: ...y information contained therein are confidential and the copyright of PRO DIG LLC Neither the whole nor any part may be disclosed loaned copied or otherwise disseminated for any purpose whatsoever wit...

Page 3: ...the hub to maintain maximum battery life The battery life of this system has been designed to exceed 10 5 month of usage running 10 hours a day 5 days a week in 20 F Battery replacement will occur au...

Page 4: ...ng from the Intelli Tork 4 Always disconnect from the Intelli Tork when finished This is to be treated as a power off procedure 5 Do not carry or hang by the USB cable 6 Do not remove the black box mo...

Page 5: ...s Thrust and Angle can be turned off 6 Zero associated readings Torque and Thrust should be zeroed at the beginning of each pile under no load 7 Depth manually increase decrease depth as pile is drive...

Page 6: ...oosen axis 7 Gyro calibration button Tap once to begin a calibration for the RPM rotations and angle parameters Ensure the unit is level and stationary prior to calibration Wait 10 seconds for the cal...

Page 7: ...individual pile log screen allows the user to advance through the log file Pressing the center button allow the user to advance through the log file in 1 6 second 1 minute and 10 minute intervals 4 Re...

Page 8: ...G USA COM 8 1 Enter new Job ID and Pile ID The current Job ID will remain in the Job ID field until modified 2 Start Logging Data After selecting return to main menu 3 Log File Information 4 Return to...

Page 9: ...values in the units displayed on the right For Cloud based reporting targets must be set to report Torque and Depth Once the Alarm value is reached the associated value s background will turn Red whil...

Page 10: ...er wireless connection to the Internet Intelli Tork Cloud Subscription is required to utilize this feature Alternatively the user may download the log files to a USB or Micro SD in a cvs file format f...

Page 11: ...view You will now see a data preview of that individual log In the upper right corner of this menu select the button labeled csv This will generate the csv file to later be down loaded To download th...

Page 12: ...12 WWW PRO DIG USA COM...

Page 13: ...785 856 2661 13 NOTES...

Page 14: ...14 WWW PRO DIG USA COM NOTES...

Page 15: ...785 856 2661 15 NOTES...

Page 16: ...1604 ROSEPORT RD ELWOOD KS 66024 785 856 2661 WWW PRO DIG USA COM PROUD MEMBER OF...

Reviews: