background image

14

 Momentum mo8 Manual

Connection and Setup

Chapter 2

Setup

Network Clock Sync

PLEASE TAKE NOTE OF THE FOLLOWING:

The Momentum network MUST have ONE mi8 that is assigned CHANNEL 1. This assignment is 

used to synchronize all of the device clocks on the network. Without this assignment, the system 

clock will not sync and audio ‘clicks’ will be heard.

The mo8 unit includes a control panel with an LED display and two push buttons (F1 and F2).  

The device can be confi gured through a series of key strokes using F1 and F2. The control panel 

will only control the local device and cannot change other units via the network.

Using the Control Panel

F1 - Mode Edit / Decrease Value

F2 - Mode Select / Increase Value

Display

Status Indicator

Power Indicator

Button/LED

Description

F1 Mode Select:

F1 activates the edit mode within a particular function.  

F2 Mode Select:

F2 generally selects which function to edit.

Power Indicator:

The power indicator shows that a power source is connected to the

Momentum units.  The LED is connected to the digital power source.

All other power sources in the system can be monitored via the PC

software.

Status Indicator:

The status indicator is a bi-color LED. GREEN indicates all Momen-

tum Network connections have been found and the network is run-

ning. RED indicates there are one of two problems;  

    1) An Ethernet link is not established or is not connected. 

    2) The audio sync packet (channel 1) is not found. 

Summary of Contents for Momentum MO8

Page 1: ...Eight Channel Analog Output Manual mo8 Pro Co Sound Inc 225 Parsons Street Kalamazoo MI 49007 1 888 253 7360 www procomomentum com...

Page 2: ...tive or dealer must perform all warranty servicing of the units otherwise all aspects of this warranty are void 2 All tamper proof seals on the unit s must be intact in order for the unit s to be serv...

Page 3: ...tion and Startup Power Network Wiring Copper Wiring Copper Connection Fiber Connection Network Configuration Setup Network Clock Sync Using the Control Panel Setting Device Start Channel IP Address Sa...

Page 4: ...hock do not expose any part of your Momentum System to rain or moisture To reduce the risk of electrical shock do not remove cover There are no user serviceable parts inside Refer servicing to service...

Page 5: ...in the successes and failures of our efforts Welcome to the Pro Co Family Upon receiving your Momentum System please check all cartons for damage If there is damage notify the shipper and dealer in t...

Page 6: ...the inherent problems that are associated with traditional wiring Flexibility and expandability are enhanced through the use of modules for inputs outputs and DSPs Signal routing becomes as easy as cl...

Page 7: ...nel XLR connectors This also allows passive splitting of the analog signals if needed Pro Co offers whatever breakout cables you need Just ask for them when you order your system mo8 Front View with o...

Page 8: ...Active Link Shows network activity 2 TX Indicates that the mo8 is transmitting data on the network 3 1000m Indicates that the mo8 is connected at one gigabit 4 Quality Indicates an acceptable Etherne...

Page 9: ...is power supply comes with three jumper cables that will allow up to four units to be linked together and powered by one MUPS The MUPS is an additional option and must be ordered separately Use a stan...

Page 10: ...opper Connection Use T568B or equivalent connectors when wiring your system This view shows the color code as viewed from the front of the female socket or the rear of the male connector Crossover wir...

Page 11: ...re endless For more information on advanced configurations and support visit www procomomentum com For further support con tact you local dealer or Pro Co technical support One to One Connection CAT5E...

Page 12: ...007 mo8 Output mo8 Output mo8 Output mo8 Output FOH CAT5E or CAT6 Optional Fiber Note Running both Fiber and CAT6 copper or two CAT6 copper connections can provide a redundant link between FOH and th...

Page 13: ...trol PC to multicast filtering Multicast MAC 01 15 AB C6 00 00 See Network Design White Papers mo8 Output Chn 001 mo8 Output Chn 009 Chn 017 Chn 025 Chn 033 Chn 041 mo8 Output mo8 Output mo8 Output mo...

Page 14: ...etwork Using the Control Panel F1 Mode Edit Decrease Value F2 Mode Select Increase Value Display Status Indicator Power Indicator Button LED Description F1 Mode Select F1 activates the edit mode withi...

Page 15: ...68 1 1 When in the idle menu state pressing the F1 button will flash the current ad dress The number shown is the LSB of the IP address 192 168 1 LSB If the network is to be controlled with a PC each...

Page 16: ...ey strokes between F1 and F2 In general F2 selects which function to edit and F1 activates the edit mode within that function The flow chart below displays each of the controlling F1 and F2 functions...

Page 17: ...press F1 F2 to exit or allow display to time out 6 To return to the beginning of the menu allow the display to time out When the display times out and when the unit is at idle the start channel numbe...

Page 18: ...3 Tap F1 to decrease value Press F2 in increase value Toggle F2 to select Clr to set the IP 4 to factory default of 192 168 1 1 Press and hold F1 and F2 to execute and save the change 5 Exit by allow...

Page 19: ...uency Response 20 20kHz 0 05dB Network Specifications Standard Gigabit Ethernet Protocol Power Over Ethernet PoE 802 3af Compliant Up to 256 total active system inputs at 48K or 96K sampling Onboard m...

Reviews: