background image

2:3  ON/OFF, PUSH BUTTONS

OK

<

>

>

To START the instrument, press OK.

The OK button is used to accept 

throughout the step by step procedure. 

To SWITCH OFF the instrument, press and 

hold OK for 3 seconds or , when in date/time 

mode, press < twice to reach the menu 

alternative SWITCH OFF INSTRUMENT? 

Accept by pressing OK.

Used to 

change 

value or 

position

Used to 

change 

value or 

position

This button 

allows you to 

step backwards 

in the menu if 

you should enter 

and accept OK 

by mistake. 

NOTE!

If the ^ button is pushed by mistake during the measurement of a cylinder, the instrument 

will step backwards in the menu with each push. It is not possible to return further back 

than to CRANKSHAFT MEASURING position (see flow scheme section 5).

2:4  SETTINGS

 

2:4.1 Set date & time

 

Date and time are continuously displayed when the instrument is switched on and 

 

controlled by an internal clock. If the battery runs empty it might be necessary to 

 

re-enter actual time and date. Date is written YY-MM-DD (Year, Month, Date). 

 

Time is entered using a 24 hour clock (no AM/PM). The date format can then be 

 

changed into US format (MM-DD-YY) if desired.

 

2:4.2 Change number of digits

 

The display is normally set 3 decimal numbers (i.e. 1/1000 mm) on the display = 4 

 

digits. It is possible to select 2 decimal numbers = 3 digits. 

 

2:4.3 Change limit value

 

Red and Green indicators are located on the instruments front panel to assist 

 

measurement. The measurement limits are normally set +/- 0.500 mm. 

 

Measurements taken within this range will show a steady green LED. 

 

Should it exceed these limits the Red LED will go on. If you want to make a visual 

 

check only, the limits can easily be reduced to acceptable tolerances indicated 

 

with Green and Red. 

 

2:4.4 Change program mode

 

When selecting STANDARD MODE by OK, the program (menu) will follow the 

 

Flow Scheme on the last page.

 

If MEASUREMENT ONLY is selected the display will show current date. 

 

By pressing OK the instrument will remain in measurement only mode.

 

NOTE ! In this mode the panel buttons operate in the following way;

 

OK = ON/OFF < = RESET > = ZERO SET ^ = BACKLIGHT on/off.

 

This mode will be retained on re-starting the instrument and can only be switched 

 

back to STANDARD MODE by pressing the > arrow button when the instrument is 

 

started and displays the current date.

 

Step to CHANGE PROGRAM MODE and change mode.

Summary of Contents for Prisma DI-5C

Page 1: ...M A N U A L I N S T R U M E N T DI 5C...

Page 2: ...uments 2 9 Edit documents 2 10 Read documents 2 11 Delete documents 2 12 Battery charge 3 Data transfer to PC 4 Optional cylinder liner measurement 5 Calibration of instrument 6 Spare parts list 7 Flo...

Page 3: ...measured object Crankshaft are having the same temperature so that the transducer temperature is not changed during the measurement If the transducer s temperature differs from the measured object Cra...

Page 4: ...suring any distance between min 89 to max 565 mm An optional transducer for down to 60 mm web distance is available however the Ovality Kit accessory cannot be used together with it All selections inf...

Page 5: ...an then be changed into US format MM DD YY if desired 2 4 2 Change number of digits The display is normally set 3 decimal numbers i e 1 1000 mm on the display 4 digits It is possible to select 2 decim...

Page 6: ...Engine No 1 to accept press OK Alternatively to generate your own engine number use arrow buttons as described above g i Select engine condition warm cold to accept press OK j Enter correct temperatu...

Page 7: ...rackets indicating the position has already been measured Should you want to return to a particular cylinder select cylinder number and press OK the display will ask if you wish to re measure the posi...

Page 8: ...y will move to DELETE ALL DOCUMENTS press OK The display will read ARE YOU SURE NO If no press OK otherwise press right arrow button to menu AREYOU SURE YES press OK to delete all documents The progra...

Page 9: ...g tip 458 5107 Extension Bar 10 mm 458 5160 Extension Bar 160 mm 458 5205 Extension Bar 20 mm 458 5402 Extension Bar 40 mm 458 5809 Extension Bar 80 mm 423 3640 Locking Ring Small 10 mm 412 2794 Locki...

Page 10: ...ORED NEW DOCUMENT NR 00000000 CRANKSHAFT MEASUREMENT MAIN ENGINE ENGINE NR 01 WARM ENGINE COLD ENGINE AUXILARY ENGINE DIESEL GENERATOR USER DEFINED OVALITY MEASUREMENT DOCUMENT NR 00000000 MEMORY IS E...

Page 11: ...OS X SAVED RETURN TO RESET CURRENT CYL NR 01 ANTI CLOCKWISE MEASUREMENT ARE TOU SURE YES DOCUMENT DELETED 00000000 MEO1 CYL 01 READ DOC DONE NEXT CYLINDER READ DOC DONE ARE YOU SURE NO COLD ENGINE B D...

Page 12: ...ethod is simply giving 5 measuring points at each level of the liner To compare the levels you will also see how much the wear of the liner is in the cylinder top Using the Prisma DI Ovality Kit toget...

Reviews: