background image

541-531revD-EN

9

Printed in USA 10/10 © 2010

Product Holding Bin

DHB-BK41/43

Set Maximum Transfer Time

A. The SET MAXIMUM TRANSFER TIME menu is used to set the amount of time allowed to make a product transfer from one pan to another.
B. Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the MENU/ENTER button until the display shows one of 

the programming menus.

C. Use the UP or DOWN Arrow button to scroll to the 

max xFR TIME

 

 

 (Set Maximum Transfer Time) menu.

1

PRINCE CASTLE LOGO Button

MENU/ENTER Button

A. Press and release the MENU/ENTER button to enter the Set 

Maximum Transfer Time menu.

B. The display shows 

max xFR :20

 

 

. This shows a value of 20 

seconds.

2

A. To change the time, use the UP or DOWN Arrow button to 

scroll to the desired time. When the desired selection is 
displayed, press the MENU/ENTER button to enter the 
selection.

B. Press and release the PRINCE CASTLE LOGO button at any 

time to exit the Program Mode and return to the Run Mode.

NOTE: If the MENU/ENTER button has not been pressed to save 
any changes, the program will revert to the original time.

3

Product Linking

Any Timer Bar (except bun holding timers) can be linked to others (see Special Programming Mode, this page). If Timer Bars are set to the same link 
group, any product started in any bar of the same group will be compared to all other products in the same group, and its LED color will be determined 
based on all timers in the group with the same product (not just with all timers on its own Timer Bar).

Special Programming Mode

A. Press and hold the PRINCE CASTLE LOGO button then immediately press and hold the MENU/ENTER button. Hold both buttons for six 

seconds. The displays will change to show the first menu — depending on model.

B. Press and release the UP and DOWN Arrow buttons to scroll through the list of Special Modes.

1

PRINCE CASTLE LOGO Button

MENU/ENTER Button

ENTR

Set Link Group

A. When the displays show 

SET LINK GRPx

 

 

 

ENTR, 

the X indicates the currently assigned Link Group. Press and release the MENU/

ENTER button to set the Link Group Mode.

B. The link group number (X) will flash. Press and release the UP and DOWN Arrow buttons to change the group number. The maximum 

number allowed is 3, and the minimum is 0. When a Timer Bar is assigned to Link Group 0, it is isolated and not associated with any other 
Timer Bar (linking is disabled).

C. When the desired link group is displayed, press and release the MENU/ENTER button to save it. The program will revert to Set Link Group 

Mode.

2

Summary of Contents for DHB-BK41/43

Page 1: ...ervice agency This warranty is subject to the following exceptions conditions Use of any non genuine Prince Castle parts voids this warranty All labor to be performed during regular work hours Overtim...

Page 2: ...15 amp 120 Volt All connections must be in accordance with local electrical codes and any other applicable codes NOTE The electrical receptacle should be a dedicated outlet No other equipment should...

Page 3: ...or REG Regular Menu will be lit depending on pre programmed menu When LED is steady RED load product and press the PAN button 4 If no other pan is active for a product the LED for the first pan loade...

Page 4: ...of 150 225 F Use the control below and the following steps to set the setpoint temperature for each heater 1 UPPER SHELF LED This LED will be lit to indicate upper shelf is selected PROG LED This LED...

Page 5: ...ount of time for temperatures to stabilize before starting calibration Press the UP or DOWN Arrow button until the desired shelf LED and upper U or lower L heater is selected A Press and hold the PRIN...

Page 6: ...ays show PROG and the PAN buttons LEDs all glow RED 1 A Press the PAN button next to the display to be changed The LED will change from RED to YELLOW and the display will change from PROG to the assig...

Page 7: ...uct Menu Details on page 11 for a list of products and their corresponding display names NOTE Holding the UP or DOWN Arrow button for longer than 2 seconds will cause the product list to automatically...

Page 8: ...C When the desired product is displayed press the MENU ENTER button to select it The first letter in this case theE will start blinking 2 When all four digits have been changed press the MENU ENTER bu...

Page 9: ...ers can be linked to others see Special Programming Mode this page If Timer Bars are set to the same link group any product started in any bar of the same group will be compared to all other products...

Page 10: ...n to scroll to the desired address Press the PRINCE CASTLE LOGO button to store the new address 4 Available addresses are BIN1 thru BIN9 BINA BINB BINC BIND BINE and BINF IMPORTANT Continue to Step 5...

Page 11: ...CRSP 45 3 Chicken Patty CHKN 60 4 Chicken Tenders TEND 30 3 Burgers BURG 60 3 Whoppers WHPR 45 3 BK Broiler BK 60 6 Bacon BACN2 120 2 Poppers POP2 30 2 Mozzarella Stick MOZ2 30 2 Spicy Chicken Wings S...

Page 12: ...flashes Opn and rEL Temperature is below 75 F Heater inoperable Probe inoperable Relay inoperable Normal display during warmup Test heater resistance 150 2 Ohms Check for open thermocouple wires from...

Page 13: ...e Kit Pkg of 10 Fuse on Main PCB 4 541 723E4S Pan Cover Kit Pkg of 4 5 155695n 12 1 3 Size Dual Handle Pans Pkg of 12 6 541 TSM4SCS Timer Bar 7 541 719S Display PCB Kit Ref Part No Description 8 541 8...

Page 14: ...C Y E L T C X X XX EXTRA TIMER BLU BLK WHT OUT IN INPU T EXTRA AUX MAIN MAIN AUX TIMERSPAN IN WHT OUT BLK SPKR J11 J22 J12 J14 J20 J5 TC JC TX J7 TC J8 TC 1 2 3 4 J1 1 J2 2 J3 3 J4 4 F2 T1 P5 P1 P2 P...

Reviews: