CAL 265
presets loaded
129 C
Steamer 625-50
5
Rev G
3
Printed in USA
1010
© 200
3
Steamer
625-M
FY
Temperature
Calibration
1
A. Press and hold the TEMPERATURE button. The display will
show the current temperature setting for Celsius (C) or
Fahrenheit (F).
B. While holding the TEMPERATURE button, press the C/F button
to change the setting between Fahrenheit and Celsius.
C. Release the TEMPERATURE button to store the new value.
3
A. Press the UP or DOWN Arrow buttons until the temperature
readout matches the calibration reading.
B. Press the McDonald’s LOGO button to store the desired
calibration
and exit CAL TEMP mode.
NOTE: Pressing the Product 3 button at any time exits the
Program mode without storing the change.
Loading factory presets restores the unit to factory settings and voids
all user programmed information.
A. During power up, press and hold both PRODUCT 1 and PRODUCT 4
buttons within 3 seconds. The display will flash PRESETS LOADED.
B. Release both buttons.
2
The CAL TEMP mode is used to calibrate the platen temperature
with an external meter connected to the meter plug inlet on the
bottom right side of the unit. Add ± 5°C (± 10°F) .
A. Press
and hold McDonald's LOGO button and immediately press
and hold the TEMPERATURE button. Hold for 6 seconds.
B. The display now shows the current
calibration temperature.
C. Press the PRODUCT 2 button to zero any previous calibration
offset value. The display will now show the platen temperature
without any calibration offset.
255 F
CAL 245
CAL 265
Factory Presets
. VERS XX.XX
View Firmware Version
Press and hold the McDonald’s LOGO button first, then press and
hold the START button.
The display will show the current firmware version.
Manual Reset
A hi-limit thermostat will turn off electrical power to the platen and
control circuits if the unit overheats.
Turn the unit off and allow to cool (approximately 10-15 minutes).
A manual reset is located on the back of the unit. Once the unit has
cooled sufficiently,
remove the cap and
press the manual reset
Manual Reset
Default Factory Presets:
ON OFF Cycles Delay
.5 1 6 2
.5
to restart unit
.
Replace the manual reset cap.
NOTE: If the unit continues to shut-off due to overheating, contact your