background image

 

                                                                                                                                             Instruction Manual VARORMAT 

 

12 

 

 

8.

 

Control keyboard indications 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Symbol 

Indication 

Message 

 

What to do 

 

 

 

 

1-"steam ON" 

The green light is on. 

The procedure of water 

 

 

heating starts. When the 

 

 

 

green light is off (in 15- 

 

 

 

18’ from 10 

o

C) steam is 

 

 

 

ready. 

 

 

 

2-"pump ON" 

The green light is on. 

The pump feeds water to 

 

 

the boiler normally. 

 

3-"Level Error" 

The red light is on. 

Problem at the water 

-Clean or replace 

 

 

level control system. 

electrodes No 46,47,48

 

 

Automatic interruption 

-Check if the electrodes 

 

 

of the machine 

wiring has been cut off. 

 

 

operation. 

 

-Replace the PC board 

 

 

 

 

 

4-"Water Error"  The red light is on 35sec 

Problem  at 

the  water  -Check the pump No 2 

 

after the starting. 

feeding or its circulation 

is faulty or stuck. 

 

 

in the machine. 

-Check if the pump's 

 

 

Automatic 

interruption  pressure is low. 

 

 

of 

the 

machine  -Clean pipes No 9 & 20 

 

 

operation. 

 

from salts & rubbish 

 

 

 

 

 

- Replace the solenoid 

 

 

 

 

 

water valve No 18

 

 

 

 

 

- Check if feedvessel No 

 

 

 

 

 

41 is empty of water. 

Button "ON" 

The green light is on. 

Machine is on function. 

 

The green light is off. 

Machine is out of 

 

 

 

function. 

 

 

Iron’s buttons 

1.The green light is on, to 

1.The machine supplies 

 

 

the left or the right 

steam to 1 iron. 

 

 

button. 

 

 

 

 

 

2.The machine supplies 

 

 

2.The green light is on, at 

steam to 2 irons. 

 

 

both buttons. 

 

 

 

 

Summary of Contents for Vapormat

Page 1: ...IRONING PRESSING MACHINERIES FUSING PRESSES Instruction Manual Vapormat CE...

Page 2: ...r 9 6 Maintenance Testing 9 6 1 Maintenance 9 6 2 Test the good operation of the machine 9 7 Troubleshooting 10 7 1 The pump does not run 10 7 2 The water is not heated while the steam lamp lights on...

Page 3: ...this operating manual You may not copy reproduce or translate this operating manual or parts of it to another language without prior written consent of Primula SA Any information in this manual may be...

Page 4: ...The serial number plate has been placed in a visible place on the steam generator and is made from fadeless material Amongst others the Serial Number plate displays the following Amongst others the Se...

Page 5: ...5 L thickness 7 1mm The water drops glide down to the bottom of the boiler Outside and inside welding of boiler to avoid oxidation Double steam outlet for 2 Irons which keeps the steam dry Water inle...

Page 6: ...ccordance with the current instruction manual and only with the accessories that are provided or that are intended for this specific Steam Generator The manufacturer is not liable for any damages resu...

Page 7: ...han the above requirements it is recommended to use ANTISCAL The lime contained in the water may be placed in the boiler and on the heating elements will cause faults The use of ANTISCAL prevents depo...

Page 8: ...e for steam preparation is 9 11 min The manometer should reach 3 5 bars The machine is ready to work Press the iron s buttons on the control keyboard Press only one button if the requested produced st...

Page 9: ...13 6 1 Maintenance Keep the machine as clean as possible Clean the inside of the machine by compressed air at least 2 times per year Depending on the quality of the water Clean periodically the electr...

Page 10: ...stem 7 3 The boiler is overheated The overheating lamp No 54 is on Wait for a while until the steam generator brings the temperature down Unscrew the black knob towards left No24 Inside there is a sma...

Page 11: ...periods steam draining is appeared in the feeder vessel No 41 Check the one way valve No 16 Clean or replace it paying attention on putting it back correctly 7 7Safety valve Check the pressostat No 1...

Page 12: ...cut off operation Replace the PC board 4 Water Error The red light is on 35sec Problem at the water Check the pump No 2 after the starting feeding or its circulation is faulty or stuck in the machine...

Page 13: ...Instruction Manual VARORMAT 13 Images of spare parts...

Page 14: ...Pressostat s coil new model since 2019 16 303 03 016 One way valve 1 2 17 303 03 017 Corner 1 2 Male Female 18 303 06 059 Corner 1 4 Male female 19 303 03 019 Condensate s pipe 20 306 11 051 Control l...

Page 15: ...p 10 16 46 193 03 046 Electrode No 1 47 193 03 047 Electrode No 2 48 193 03 048 Electrode No 3 49 303 03 049 Grounded terminal block 6 poles 50 193 06 042 Pipe of safety valve 51 303 03 051 Water inle...

Page 16: ...Instruction Manual VARORMAT 16 Wiring diagram...

Page 17: ...2 E V Solenoid water valve V2 Solenoid steam valve No 1 V3 Solenoid steam valve No 2 PM Water pump 0 5HP Water pump 0 7HP E1 Water level electrode max E2 Water level electrode min E3 Heating protecti...

Page 18: ...ealer you have purchased the machine from or us directly at 14th km Thessaloniki Kilkis 57200 Liti Thessaloniki Greece Tel 30 23940 71 215 Fax 30 23940 71 438 E mail info primula gr All specifications...

Reviews: