Then press the button "Set position to 0", a new window is opened in which
confirmation is requested "Set current position to minimum?”. By confirming with
OK we have set the minimum point of focuser travel. Now in the opposite direction,
with the "Slow -“ and "Slow +" or "Fast -“ and "Fast +" buttons, move your focuser
to the outermost position. As before, stop 1 or 2 mm before the end of travel
(remembering to avoid letting go of the engine at the end of the travel as it may
brake your focuser or SESTO SENSO motor) by pressing the STOP button. Press the
"Set position to MAX" button, as before appears a new window that asks you to
confirm that the current position is the maximum position "Set current position to
maximum?”. Press OK and SESTO SENSO calibration will be done.
WARNING: never disconnect the USB or power cable
between the EAGLE CORE and SESTO SENSO while the
"ACT" LED is on, ALWAYS turn off EAGLE CORE by using
the off button and wait until the "ACT" LED is off before
removing the power to EAGLE CORE. If one of the above
conditions occurs, the calibration procedure must be
repeated to avoid breaking the SESTO SENSO focuser or motor.
NOTA: if, after calibration, you move the focuser by hand (this way loosing the
calibration), manually move the focuser in innermost position and press the “Set
position to 0” button.
74