background image

M3

Rotate the top knurled knob counter 

clockwise to tighten and secure the 

contact. There should now be a gap 

between the two knurled knobs.

M2

Insert the power feed into the track and 

rotate the bottom knurled knob 

counter clockwise until the feed rest 

perpendicular to the track.

M1

Neutral Installation Instructions

Ensure that there is NO gap in between 

both knurled knobs prior to installation.

L3

Rotate the bottom knurled knob 

counter clockwise to tighten and 

secure the contact. The gap between 

the two knurled knobs should now be 

smaller.

L2

Insert the power feed into the track and 

rotate the top knurled knob counter 

clockwise until the feed rest 

perpendicular to the track.

Ensure that the top knurled knob is 

raised as much as possible prior to 

installation.

L1

Designed only for the 

bottom track in the 

vertical orientation.

pr

ima fit II sy

st

em

general installation instructions part 6 of 6

Follo
w all local and na

tional elec

tr

ical c

odes

.

For assistanc

e please call P

rima C

ust
omer S

er

vic

e a

t 562-407-3079

NEUTRAL

HOT

Designed only for the 

bottom track in the 

vertical orientation.

HOT Installation Instructions

Wire must be fed

Wire must be fed

CAUTION
Always disconnect power prior to installation 

or maintenance.

NOTE:

 

1. Both the Neutral and the Hot must be inserted into the same track in order to receive voltage.

2. Test Voltage and Temperature after installation to ensure proper installation and conductivity.

3. Remove the power feed before moving to ensure finish of track.

Voltage & Temperature Readings

Voltage: 11.3V 1 11.7V w/ 85% to 90% load

Temperature: 80° - 90°F Room Temperature

This additional piece is 

necessary for Fit II 

application. 

13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com

fit II system support for vertically oriented track 

IMPORTANT  Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for fixtures. 

Prima is not responsible for any fixture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on 

which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties 

are void if Prima transformers are not used. Prima’s catalogs provide general information and suggestions for proper dimmer usage. Please consult 

our customer service department with any questions regarding dimmer specifics. Prima is not responsible for any damage caused by improper 

dimmer specification and usage. Use only qualified electrician for installation. Adhere to all local and national electrical codes prior to installation.

It is strongly recommended that gloves are used when handling the FIT II System track. Oils and dirt from fingers can sometimes permanently

mark the finish. Track should be cleaned with a damp cloth and thoroughly dried before fixture installation.

fit II system two piece power feed

IMPORTANT  Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for fixtures. 

Prima is not responsible for any fixture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on 

which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties 

are void if Prima transformers are not used. Prima’s catalogs provide general information and suggestions for proper dimmer usage. Please consult 

our customer service department with any questions regarding dimmer specifics. Prima is not responsible for any damage caused by improper 

dimmer specification and usage. Use only qualified electrician for installation. Adhere to all local and national electrical codes prior to installation.

It is strongly recommended that gloves are used when handling the FIT II System track. Oils and dirt from fingers can sometimes permanently

mark the finish. Track should be cleaned with a damp cloth and thoroughly dried before fixture installation.

(22-79300-2)

REV. 052416

Summary of Contents for FIT II

Page 1: ...ORTANT SAFETY INSTRUCTIONS IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PRODUCT PLEASE CALL PRIMA CUSTOMER SERVICE AT 1 562 407 3079 INSTALLATION INSTRUCTION A READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIT II SYSTEM B DO NOT INSTALL THIS SYSTEM IN DAMP OR WET LOCATIONS C DO NOT INSTALL THIS SYSTEM OR ANY PART WHICH CONTAINS EXPOSED WIRES LESS THAN 7 FEET FRO...

Page 2: ...ity and well known name brands We will normally send 50W MR16 for spotlights and 50W Xelogen G6 35 lamp for pendants unless otherwise specified differently in the catalog Prima will also ship according to customers specific lamp type or wattage per order Lamps are complimentary thus we will not offer free replacements nor will we issue any credit for lamps However customers may purchase lamps from us...

Page 3: ...ting elements and reset the breaker 2 Attempt to turn the system on If the system still trips look inside the transformer housing and make sure all connections are secure and that there is no short If the system stays on you most likely have a problem with one of the lighting elements Re install one element at a time and check if the system works to find the defective element Ensure that the lighti...

Page 4: ...CUTTING BLADE Be sure to deburr and clean all cuts prior to final assembly fit II system track connector powerfeed basics B1 B2 Connectors are available for extending track length turning corners or creating intersections in the run Great care must be taken to ensure the connector is installed properly FIT II track is constructed of an aluminum housing which doubles as the neutral conductor The sl...

Page 5: ...ssure creates a solid and secure mounting IMPORTANT Do not attempt to slide the adapter to other locations on the track length after it is installed The adapter must be completely removed from the track slot and reinstalled at the new location Insert the adapter into the track slot Apply pressure and rotate 90º clockwise After rotation adapter rests inside track slot Rotate knurled locking ring cl...

Page 6: ... point Mounting screws Anchors E Track Support End Mount Insert the Track Support End Mount to the end of the track and tightened the screw with a screwdriver Insert the screw anchor and tighten the screw Be sure that the items indicated below are included in the package Insert the Track Support End Mount to the end of the track and tighten it with a screw driver Do both ends before mounting it on...

Page 7: ...he side 22 79122 or the top 22 79123 Insert the connector into open end of a FIT track length Secure the powerfeed by tightening the set screws with a flat head screwdriver at the top and bottom of the connector Insert the transformer s low voltage secondary leads into the power entry holes on the connector Using the supplied hex wrench secure the transformer leads by tightening two set screws for...

Page 8: ... conductive 22 79132 or non conductive 22 79133 inserts into the conductor hole on one of the track lengths Insert the top and bottom cover half way into the same track length and secure by tightening the set screws with a flat head screwdriver Connect the second track length and secure by again tightening the set screws with a flat head screw driver There should be no space between the connected ...

Page 9: ...r installation to ensure proper installation and conductivity 3 Remove the power feed before moving to ensure finish of track Voltage Temperature Readings Voltage 11 3V 1 11 7V w 85 to 90 load Temperature 80 90 F Room Temperature This additional piece is necessary for Fit II application 13615 Marquardt Ave Santa Fe Springs CA 90670 Ph 562 407 3079 Fx 562 407 3069 www primalighting com fit II syste...

Page 10: ...y questions installation Adhere to all local and national electrical codes prior to installation IMPORTANT USE ONLY LOW VOLTAGE DIMMERS WITH MAGNETIC TOROIDAL TRANSFORMERS Prima recommends the use of 10AWG THHN wire to maintain 25 amp capacity Note Using a dimmer may shorten the secondary length distance Class I ELECTRONIC TRANSFORMERS ARE DIMMABLE Prima recommends the use of 10AWG standard wire o...

Reviews: