If your system does not turn on:

  ALWAYS check the fuse or thermal breaker first. Fuses and breakers are easily replaced and can be bought from any 

local electrical distributor or directly from Prima Lighting. BYPASSING A FUSE OR THERMAL BREAKER CAN RESULT IN FIRE!!

• Check all switches and breakers, including the main panel bre

aker and the breaker button on the transformer.

 

Make sure all wire connections and piercing contacts are tight and well connected (transformer to conductor leads, 

junction box, connectors between rails).

• Check the output side of the transformer with a multimeter and make sure the power is there.

• Check that the bulbs and sockets are installed securely and a

re not burned out.

 

The system will shut down if it is overloaded. Make sure that the total wattage of the lamp elements does not exceed 

the transformer’s maximum wattage rating.

 

The system will shut down if there is a short. Make sure that the rail and elements are not coming in contact with any 

other metal surfaces and that each element is installed properly.

Common Troubleshooting on TRANSFORMER and BREAKERS

If the breaker at the transformer is tripping, please follow these troubleshooting steps:

1. Remove all lighting elements and reset the breaker.

2. Attempt to turn the system on.

If the system still trips,

 look inside the transformer housing and make sure all connections are secure and that there is no 

short. If the system stays on, you most likely have a problem w

ith one of the lighting elements. Re-install one element at 

a time and check if the system works to find the defective element. Ensure that the lighting socket is okay, wires are not 

stripped or shorted, and the lamps are within the allowed watta

ge.

If the breaker at the main panel keeps tripping 

when the system is first turned on, you may need to replace thi

 

breaker with an inductive breaker, or you may have a short on the 120 volt side of the transformer.

Nuisance Tripping

Sometimes, for no apparent reason, the secondary circuit breakers on the transformers will trip. Some things to consider:

1. 

Allow a 20% safety factor in estimating your load wattage. The bulbs often sometimes carry a load of up to 5% more than 

specified, wire length, gauge, and connection variation may impact the actual load. Using proper wire nuts and 

ensuring wires have 1/2” long contacts length are essential to 

minimize loading.

by your local electrical codes (use the 20% safety factor as mentioned above), and all transformers should be mounted

as designed.

3. If using a dimmer, use a compatible low-voltage dimmer only.

If using remote magnetic transformer, the transformer has to be mounted vertically with the breakers facing downward

 for better heat dissipation.

REV. 052416

Summary of Contents for FIT II

Page 1: ...ORTANT SAFETY INSTRUCTIONS IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PRODUCT PLEASE CALL PRIMA CUSTOMER SERVICE AT 1 562 407 3079 INSTALLATION INSTRUCTION A READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIT II SYSTEM B DO NOT INSTALL THIS SYSTEM IN DAMP OR WET LOCATIONS C DO NOT INSTALL THIS SYSTEM OR ANY PART WHICH CONTAINS EXPOSED WIRES LESS THAN 7 FEET FRO...

Page 2: ...ity and well known name brands We will normally send 50W MR16 for spotlights and 50W Xelogen G6 35 lamp for pendants unless otherwise specified differently in the catalog Prima will also ship according to customers specific lamp type or wattage per order Lamps are complimentary thus we will not offer free replacements nor will we issue any credit for lamps However customers may purchase lamps from us...

Page 3: ...ting elements and reset the breaker 2 Attempt to turn the system on If the system still trips look inside the transformer housing and make sure all connections are secure and that there is no short If the system stays on you most likely have a problem with one of the lighting elements Re install one element at a time and check if the system works to find the defective element Ensure that the lighti...

Page 4: ...CUTTING BLADE Be sure to deburr and clean all cuts prior to final assembly fit II system track connector powerfeed basics B1 B2 Connectors are available for extending track length turning corners or creating intersections in the run Great care must be taken to ensure the connector is installed properly FIT II track is constructed of an aluminum housing which doubles as the neutral conductor The sl...

Page 5: ...ssure creates a solid and secure mounting IMPORTANT Do not attempt to slide the adapter to other locations on the track length after it is installed The adapter must be completely removed from the track slot and reinstalled at the new location Insert the adapter into the track slot Apply pressure and rotate 90º clockwise After rotation adapter rests inside track slot Rotate knurled locking ring cl...

Page 6: ... point Mounting screws Anchors E Track Support End Mount Insert the Track Support End Mount to the end of the track and tightened the screw with a screwdriver Insert the screw anchor and tighten the screw Be sure that the items indicated below are included in the package Insert the Track Support End Mount to the end of the track and tighten it with a screw driver Do both ends before mounting it on...

Page 7: ...he side 22 79122 or the top 22 79123 Insert the connector into open end of a FIT track length Secure the powerfeed by tightening the set screws with a flat head screwdriver at the top and bottom of the connector Insert the transformer s low voltage secondary leads into the power entry holes on the connector Using the supplied hex wrench secure the transformer leads by tightening two set screws for...

Page 8: ... conductive 22 79132 or non conductive 22 79133 inserts into the conductor hole on one of the track lengths Insert the top and bottom cover half way into the same track length and secure by tightening the set screws with a flat head screwdriver Connect the second track length and secure by again tightening the set screws with a flat head screw driver There should be no space between the connected ...

Page 9: ...r installation to ensure proper installation and conductivity 3 Remove the power feed before moving to ensure finish of track Voltage Temperature Readings Voltage 11 3V 1 11 7V w 85 to 90 load Temperature 80 90 F Room Temperature This additional piece is necessary for Fit II application 13615 Marquardt Ave Santa Fe Springs CA 90670 Ph 562 407 3079 Fx 562 407 3069 www primalighting com fit II syste...

Page 10: ...y questions installation Adhere to all local and national electrical codes prior to installation IMPORTANT USE ONLY LOW VOLTAGE DIMMERS WITH MAGNETIC TOROIDAL TRANSFORMERS Prima recommends the use of 10AWG THHN wire to maintain 25 amp capacity Note Using a dimmer may shorten the secondary length distance Class I ELECTRONIC TRANSFORMERS ARE DIMMABLE Prima recommends the use of 10AWG standard wire o...

Reviews: