background image

general installation instructions part 1 of 6

(22-79111, 22-79113)

Follow all local and national electrical codes.

For assistance please call Prima Customer Ser

vice at 562-407-3079

A1

A2

IMPORTANT  Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for fixtures. 

Prima is not responsible for any fixture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on 

which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties 

are void if Prima transformers are not used. Prima’s catalogs provide general information and suggestions for proper dimmer usage. Please consult 

our customer service department with any questions regarding dimmer specifics. Prima is not responsible for any damage caused by improper 

dimmer specification and usage. Use only qualified electrician for installation. Adhere to all local and national electrical codes prior to installation.

It is strongly recommended that gloves are used when handling the FIT II System track. Oils and dirt from fingers can sometimes permanently

mark the finish. Track should be cleaned with a damp cloth and thoroughly dried before fixture installation.

Determine whether the FIT II track length will be installed as 

part of a series of connected track lengths or as a single 

stand alone track length. Before attempting to field cut the FIT track, 

ensure that the end caps are firmly installed into both ends. If an end 

cap has become loose during shipping, replace it.

FOR FIELD CUTTING. Cut the track so that the desired effect 

and lengths can be achieved. FIT II track may be field cut with 

an ordinary hacksaw. Be sure to use a FINE-TOOTH METAL CUTTING 

BLADE. Be sure to deburr and clean all cuts prior to final assembly.

fit II system track connector/powerfeed basics

B1

B2

Connectors are available for extending track length, turning corners or creating intersections in the run. Great care must be taken to ensure 

the connector is installed properly.

FIT II track is constructed of an aluminum housing which 

doubles as the neutral conductor. The slot of the track includes

one conductor  and one insulator. The slots may used as two separate  

circuits with the proper use of power feeds.

When installing a connector or power feed, place the opposite 

end of the track length against a solid flat surface to keep the 

internal parts of the track from sliding. Carefully align the connector pins 

on the connector with the holes in the track’s conductors. Insert the 

connector all the way into the track until it stops. 

Track housing/

Neutral

Conductor

Insulator 

B3

B4

When installing a connector at the end of a FIT II track length, 

great care should be taken to ensure the connector is properly 

installed. After the connector has been inserted into the end of the track, 

inspect the opposite end of the track. If the inslulators and conductors 

are flush with the end, then the installation was successful. If the 

conductors protrude past the end of the track AT ALL then connector is 

not properly installed. 

When the connector or power feed is properly inserted into the 

track length, secure the installation by tightening the lock 

screws located at the top or bottom of connector. DO NOT 

OVERTIGHTEN THE SCREWS.

Opposite end after a 

proper connector installation.

Opposite end after an 

improper connector installation.

FIT II SYSTEM TRACK 

MAY NOT BE BENT IN 

ANY WAY

FIT II System track 

may not be bent

13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com

*Caution:

Do not break the insulator inside
the chamber while using the 
screw-in function. Broken insulator
will cause short of circuit. 

*Caution

REV. 052416

Summary of Contents for FIT II

Page 1: ...ORTANT SAFETY INSTRUCTIONS IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PRODUCT PLEASE CALL PRIMA CUSTOMER SERVICE AT 1 562 407 3079 INSTALLATION INSTRUCTION A READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIT II SYSTEM B DO NOT INSTALL THIS SYSTEM IN DAMP OR WET LOCATIONS C DO NOT INSTALL THIS SYSTEM OR ANY PART WHICH CONTAINS EXPOSED WIRES LESS THAN 7 FEET FRO...

Page 2: ...ity and well known name brands We will normally send 50W MR16 for spotlights and 50W Xelogen G6 35 lamp for pendants unless otherwise specified differently in the catalog Prima will also ship according to customers specific lamp type or wattage per order Lamps are complimentary thus we will not offer free replacements nor will we issue any credit for lamps However customers may purchase lamps from us...

Page 3: ...ting elements and reset the breaker 2 Attempt to turn the system on If the system still trips look inside the transformer housing and make sure all connections are secure and that there is no short If the system stays on you most likely have a problem with one of the lighting elements Re install one element at a time and check if the system works to find the defective element Ensure that the lighti...

Page 4: ...CUTTING BLADE Be sure to deburr and clean all cuts prior to final assembly fit II system track connector powerfeed basics B1 B2 Connectors are available for extending track length turning corners or creating intersections in the run Great care must be taken to ensure the connector is installed properly FIT II track is constructed of an aluminum housing which doubles as the neutral conductor The sl...

Page 5: ...ssure creates a solid and secure mounting IMPORTANT Do not attempt to slide the adapter to other locations on the track length after it is installed The adapter must be completely removed from the track slot and reinstalled at the new location Insert the adapter into the track slot Apply pressure and rotate 90º clockwise After rotation adapter rests inside track slot Rotate knurled locking ring cl...

Page 6: ... point Mounting screws Anchors E Track Support End Mount Insert the Track Support End Mount to the end of the track and tightened the screw with a screwdriver Insert the screw anchor and tighten the screw Be sure that the items indicated below are included in the package Insert the Track Support End Mount to the end of the track and tighten it with a screw driver Do both ends before mounting it on...

Page 7: ...he side 22 79122 or the top 22 79123 Insert the connector into open end of a FIT track length Secure the powerfeed by tightening the set screws with a flat head screwdriver at the top and bottom of the connector Insert the transformer s low voltage secondary leads into the power entry holes on the connector Using the supplied hex wrench secure the transformer leads by tightening two set screws for...

Page 8: ... conductive 22 79132 or non conductive 22 79133 inserts into the conductor hole on one of the track lengths Insert the top and bottom cover half way into the same track length and secure by tightening the set screws with a flat head screwdriver Connect the second track length and secure by again tightening the set screws with a flat head screw driver There should be no space between the connected ...

Page 9: ...r installation to ensure proper installation and conductivity 3 Remove the power feed before moving to ensure finish of track Voltage Temperature Readings Voltage 11 3V 1 11 7V w 85 to 90 load Temperature 80 90 F Room Temperature This additional piece is necessary for Fit II application 13615 Marquardt Ave Santa Fe Springs CA 90670 Ph 562 407 3079 Fx 562 407 3069 www primalighting com fit II syste...

Page 10: ...y questions installation Adhere to all local and national electrical codes prior to installation IMPORTANT USE ONLY LOW VOLTAGE DIMMERS WITH MAGNETIC TOROIDAL TRANSFORMERS Prima recommends the use of 10AWG THHN wire to maintain 25 amp capacity Note Using a dimmer may shorten the secondary length distance Class I ELECTRONIC TRANSFORMERS ARE DIMMABLE Prima recommends the use of 10AWG standard wire o...