BEST BOY
®
HP SPOT LUMINAIRE USER MANUAL
67
Adjusting Lamp
After a new lamp is installed, the lamp must be aligned to optimize the beam. Adjustment controls are located on the
backcap.
Tools:
#2 Phillips screwdriver
optional
: 5/16"-1/2" telescoping gauge (http://www.mcmaster.com/#inside-micrometers/=r6gx02 - item # 2081A6)
WARNING:
Backcap may be HOT during lamp operation.
To adjust lamp:
Step
1. Power up luminaire and allow to warm up for at least ten minutes.
Step
2. Set intensity to 100%.
Step
3. Position beam on a white wall at a distance of 10' to 20'.
Step
4. At backcap, use three adjustment screws to optimize beam (
Figure 4-3: Adjusting the Lamp
Note:
Be sure to reset Lamp Hours when installing a new lamp.
DO NOT OPERATE WITHOUT
IN PLACE OR WHEN LENS IS
COMPLETE LAMP ENCLOSURE
DAMAGED.
RISK OF EXPOSURE TO EXCESSIVE
ULTRAVIOLET RADIATION
SOURCE DE RAYONNEMENT UV
FOR 5 MINUTES. DISCONNECT FIXTURE BEFORE RELAMPING OR SERVICING.
NE PAS ENLEVER L’ECRAN DE
PROTECTION
DANGER: INTENSE HEAT. AVOID CONTACT BY PERSONS AND MATERIALS
COUPER L’ALIMENTATION AVANT LE DEPANNAGE
INSTALL LAMP NIPPLE TOWARD REAR OF FIXTURE.
RISK OF FIRE: USE WITH MAX
1500 WATT LAMP. USE ONLY A
HIGH-PRESSURE LAMP OF DOUBLE-ENDED
TYPE HTI 1500W METAL HALIDE.
DANGER: CHALEUR INTENSE. EVITER TOUT CONTACT ET TENIR TOUTE
MATIERE A L’ECART
WARNING: RISK OF POSSIBLE LAMP EXPLOSION. ALLOW HOUSING TO COOL
ATTENTION: UTILISER UNE
LAMPE 1500 WATTS DOUBLE-CLOS
TYPE HTI METAL HALIDE.
LAMP ADJUST
LAMP ADJUST
LAMP ADJUST
LOOSEN FOR
LAMP ACCESS
LOOSEN FOR
LAMP ACCESS
CAUTION