9.
What
to
do
in
case
of
faults
04/2015
S.
72
No.:
Message:
Cause:
Remedy:
Resp.
person
8026
Binding
wire
in
middle
broken
on
right
This
message
appears
if:
the
binding
wire
middle
right
is
broken,
or
the
"binding
wire
middle
right"
proximity
switch
is
faulty.
Attention
special
feature
!!!!
Replace
wire
or
thread
in
anew.
Clean
proximity
switch
Change
if
necessary
Operator
*
Operator
*
Skilled
personnel
8027
Binding
wire
on
right
broken
This
message
appears
if:
the
binding
wire
on
the
right
is
broken,
or
the
"binding
wire
right"
proximity
switch
is
faulty.
Attention
special
feature
!!!!
Replace
wire
or
thread
in
anew.
Clean
proximity
switch
Change
if
necessary
Operator
*
Operator
*
Skilled
personnel
8031
Error
in
the
"compactor
forward"
function
This
error
message
appears
if:
The
"ram
forward"
valve
is
switched
on
for
longer
than
40
seconds
without
interruption
in
automated
operation
.
Possible
cause:
Material
jam
Channel
cylinder
not
relieving
Pressure
sensor
defect
Press
"Confirm"
button,
selection
switch
on
manual,
withdraw
press
shield
and
remove
the
material
jam
using
appropriate
mechanical
aids
(rods,
pliers,
hooks)
Valve
control
defect
Change
pressure
sensor
Operator
*
Skilled
personnel
Skilled
personnel
8032
Error
in
the
"compactor
backwards"
function
This
error
message
appears
if:
The
"ram
backward"
valve
is
switched
on
for
longer
than
40
seconds
without
interruption
in
automated
operation
.
Possible
cause::
Pressing
plate
fastened
Check
cutting
gap
and
adjust
In
case
of
no
remedy
Operator
*
Inform
customer
service
8033
Error
in
the
needle
up
function
This
error
message
appears
if:
The
"needle
up"
valve
is
switched
on
for
longer
than
8
seconds
without
interruption
in
automated
operation.
The
PLC
attempts
to
remove
the
blockages
by
briefly
moving
back
automatically
and
then
forward
again.
If
this
is
not
successful
even
at
the
4th
attempt,
this
message
appears.
Cause:
‐
Needle
channel
clogged
‐
Lower
wire
jammed
‐
Proximity
switch
defect/
wrongly
set
‐
Joint
thrust
needle
defect
Clean
needle
channel
Release
lower
wire
Clean
proximity
switch
Change
if
necessary
Change
joint
thrust
needle
Operator
*
Operator
*
Operator
*
Skilled
personnel