Block diagram
The Room Unit controls the heating and the domestic hot
water tank. This unit combines the functions of remote
control of the boiler and of the heating circuits and the room
thermometer. The Room Unit displays all the information
on the status of the system, so that you can choose from
various heating functions. The unit enables up to 3 weekly
schedule programs both for heating and for domestic hot
water.
In this configuration, the boiler continuously adapts its
operation to the outside temperature while taking the indoor
temperature into account.
INSTALLATIoN
prestige
AF120
Room Unit
Equipment required as options
Item
Code
Description
10800034
room unit rsc
Delivered with outdoor sensor
1x
1x
10800036
clip-in interface rmcIeBV3
Enables communication between the MCBA
and the Room Unit RSC.
1x
1x
10510100
outside temperature sensor, 12k
Ω
— af120
1x
1x
10800104
2 circuit manifold dn32:
With built-in wall mounts.
1x
10800107
high temperature kit dn32:
Includes: a circulator, two isolation valves,
the check valve and two thermometers.
1x
2x
10800142
manifold connection kit dn32
Includes: two stainless steel hoses Ø 6/4"
with two reducers Ø 5/4"
1x
1x
5476g003
sensor ntc 12k
Ω
:
Monitors the external domestic hot water tank.
1x
confIguratIon 2:
Installing a heating circuit and, optionally, a domestic hot water tank with regulation by a room
unit and an outdoor sensor.