61
Alarm no. Display message
Fault Alarm Description
Cause of problem
F29
Uart1 txFifo
X
UART1 send buffer is full
distortion on info bus
F30
F31
F32
BasicPControl N/A
X
BasicPController not available
Check software version and
CAN-bus connection
F33
Software ver.
X
Software version between
PressDisplay and
BasicPControll is different.
Update the software of the
display and controller.
F34
Boiler prot off
X
Boiler alarm is switched off
Press button 'B' to switch on the
boiler alarm again
F35
Span config
X
X
Span high is lower than Span
low.
Check configuration
F36
External ADC
X
X
A/D converter defect.
Send the controller to the dealer
for repair
F37
F38
F39
Lcd button
X
Button was pressed during
startup
Release the button and restart
the system
F40
F41
Sensor 1
X
X
pressure sensor 1 defect.
Check pressure sensor (cable,
sensor,
connection)
F42
Sensor 2
X
X
pressure sensor 2 defect.
F43
F44
F45
F46
F47
F48
F49
F50
F51
F52
F53
F54
F55
Taskfifo
X
Internal error.
F56
Summary of Contents for HORNIT N2
Page 2: ...2...