55
7.3 Faults and alarm messages
The following tables show the most important error and alarm messages that may appear on the
Touchscreen and PRESS-display. A description is given for each message. The table also indicates for each
message whether it is an error and/or an alarm.
7.3.1
Fault and alarm messages for the PressControl (ECONOMY A and ECONOMY DUO)
This table of faults and alarms is based on software version: PRESSCONTROL 5.0
Error
Display
Fault Alarm Description
Problem
F01
Eeprom addresss
X
Read/write error in the
permanent settings memory
(EEPROM)
During reading or writing a setting
something went wrong.
Check the settings
F02
Eeprom R/W
X
F03
Eeprom adr0
X
F04
Configuration
X
Checksum error
F05
CAN TxBuffer
X
CAN-bus send buffer full
Check CAN-bus and adjust the
macro interval if needed.
F06
CAN RxBuffer
X
CAN-bus recieve buffer full
F07
Config base
X
Base value does not correspond.
The software is new, first boot.
Else, the Eeprom memory has nog
been written properly.
F08
x
X
X
F09
First boot
X
First boot, new configuration.
F10
x
X
x
F11
CAN-bus halt
X
CAN-bus halt detected.
One of the devices on the bus has
a fatal CAN error or has rebooted.
F12
WaterIn timeout
X
Feedpump controlled to long.
Problem with the automatic
fill/relief installation.
F13
WaterOut timeout
X
Water output controlled to long.
F14
Waterlevel min
X
X Water below minimum level.
Add water
F15
Waterlevel max
X
X Water above maximal level.
Drain water
F16
Waterlvl lower
X
Water above water lower level
Drain water
F17
Waterlvl higher
X
Water below water lower level
Add water
F18
Nit pressure min
X
X System pressure below minimum
level
System pressure not in order. Call
service technician.
F19
Nit pressure max
X
X
System pressure above
maximum level.
F20
N2 in timeout
X
Blow in valve controlled to long.
F21
N2 out timeout
X
Relief valve controlled to long.
F22
Main power error
X
System rebooted.
x
F23
Compr. Thermic
X
Compressor thermic error
Compressor error:
Check compressor
Call service technician
F24
Compr. Temp
X
Compressor temperature error
F25
Compr ox empty
X
Compressor low air pressure
F26
Compr. Drivetime
X
Compressor controlled to long.
F27
N2srv connection
X
N2 server connection error.
Check CAN-bus ext. device
F28
Uart1 rxFifo
X
UART receive buffer full
Too much debug information send
or noise on the line.
F29
Uart1 txFifo
X
UART send buffer full
F30
RTC comm.
X
Internal clock defective
Send board in for repair.
F31
Set date time
X
Internal clock is not set
Set up the clock via service menu.
F32
PressControl N/A
X
PressController not available.
Check the SW version of the CAN-
bus.