33
for an optimum transmission quality. Adjustable level from 1 (high level) to 9 (low
level) by rotating the channel knob. corresponds to the Sensitivity
L
evel.
-
Anti-Vox
: allows disabling the transmission generated by the surrounding noise.
The level is adjustable from 0 (Off) to 9 (low level) by rotating the channel knob.
corresponds to
A
nti-vox Level.
-
Delay time
: allows avoiding the sudden cut of the transmission by adding a delay
at the end of speaking. The level is adjustable from 1 (short delay) to 9 (long delay)
by rotating the channel selector. corresponds to Delay
T
ime.
Once the adjustments are done, press during 1 second the
VOX
key in order to quit
the
Vox Adjustment
mode.
8) HI-CUT
Eliminates high frequency interferences. Has to be used in accordance with the
reception conditions. A short press activates the
HI-Cut
filter and
«HIC»
appears on
the display. A new press disables the function and
«HIC»
disappears.
ANL FILTER (Automatic Noise Limiter)
The transceiver is equipped with an automatic filter which reduces back ground
noises and some reception interferences in AM.
9) ROGER ~ SCAN
ROGER
(short press)
The icon « » appears on the display when the function is active. The
Roger Beep
sounds when the
PTT
switch of the microphone is released in order to let your corre-
spondent speak. Historically as CB is a «simplex» communication mode, it is not possible
to speak and to listen at the same time (as it is the case with a telephone). Once
someone had finished talking, he said “Roger” in order to prevent his correspondent
that it was his turn to talk. The word “Roger” has been replaced by a significant beep.
There comes
“Roger beep”
from.
Note:
the
Roger beep
also sounds in the loudspeaker if the
KEY BP
function is active.
If the
KEY BP
function is not active, only the correspondent can hear the
Roger Beep
.
SCAN
(long press)
Channel research:
Allows activating the
SCAN
function (research of the channels) in
an increasing way.
«SCN»
is displayed. The scanning stops as soon as there is a busy
channel. The scanning automatically starts 3 seconds after the end of the transmission
and no key is activated during 3 s. The scanning starts again in an increasing way
by turning the rotary knob to the right, or in a decreasing way by turning the rotary
knob to the left.
A new long press on
SCAN
disables the
SCAN
function.
10) STORE ~ MEM
STORE
(long press)
Allows to memorize an emergency channel with following parameters: HI-CUT.
To memorize:
Select the channel to be memorized.
- press 1 second the
MEM
key;
«MEM»
appears in the display. If the
KEY BP
function is
activated a long beep confirms the saving.
To delete a memory:
- switch off the transceiver.
- keep the
MEM
key pressed and switch on the transceiver.
- the memory is deleted.
MEM
(short press)
To recall a memory:
- press
MEM
shortly,
«MEM»
appears on the display. If the
KEY BP
function is activated
a beep sounds. The memorized channel is activated. Short press again
MEM
to go
back to previous operating channel.