ALIGNMENT VCO/PLL
1 - Alignment procedure(13,2V;configuration”
EU, PL, d, EC, U, In
”)
STEP
CONDITION
ADJUSTMENT
REMARKS OF ADJUSTMENT
1
AM/FM(EU)
RX mode
Channel 20
L304
Clarifier center position
Connect a frequency counter to TP302,
adjust L304 to reach 37,900MHz ± 20Hz
2
USB(EU)
RX mode
Channel 20
L306
Clarifier center position
Connect a frequency counter to TP303,
adjust L306 to reach 10,6975MHz ± 20Hz
3
LSB(EU)
RX mode
Channel 20
L307
Clarifier center position
Connect a frequency counter to TP303,
adjust L307 to reach 10,6925MHz ± 20Hz
4
AM/FM(EU)
TX mode
Channel 20
L305
Clarifier center position.Connect a
frequency counter to the dummy load,
adjust L305 to reach 27,205MHz ± 20Hz
5
FM(U)
TX mode
Channel 20
RT302
Clarifier center position.Connect a
frequency counter to the dummy load,
adjust RT302 to reach 27,78125MHz ±
20Hz
6
AM(EU)
RX mode
Channel 40
Clarifier center position.
Connect a
voltmeter to TP 301 and check
1,4V±0,2V.
7
AM(EU)
RX mode
Channel 01
Clarifier center position.
Connect a
voltmeter to TP 301 and check
1,2V±0,2V.
8
AM/FM
RX mode
(EU,PL,d,EC,U,In)
Clarifier center position
Connect a frequency counter to TP302,
and check with the frequency list
Summary of Contents for GRANT II PREMIUM
Page 1: ...GRANT II PREMIUM SERVICE MANUAL...
Page 11: ...TP 303 TP 302 TP 301 L 304 RT 302 L 307 L 305 L 306 ALIGNMENT VCO PLL...
Page 16: ...ALIGNMENT RECEIVER TP 1 L 19 RT 1 RT 3 RT2...
Page 17: ...GRANTII PREMIUM BLOC DIAGRAM...
Page 19: ...GRANTII PREMIUM SCHEMATIC DIAGRAM...
Page 20: ...ASC ASC IN ASC OUT RT 1 PRE...
Page 22: ...PRE...
Page 23: ...PRE...
Page 24: ...PRE...
Page 25: ...GRANTII PREMIUM COMPONENT LAYOUT...
Page 26: ...PRE...
Page 27: ...PRE...
Page 28: ...PRE...
Page 29: ...PRE...