ALIGNMENT PROCEDURE
(GRANT II PREMIUM)
* VCO/PLL PORTION
- Alignment procedure
- Test points
- Frequencies chart
* TRANSMITTER
- Alignment procedure
- Test points
* RECEIVER
- Alignment procedure
- Test points
Test equipement required
Frequency
counter
200
Mhz
HF
Generator
DC
Volmeter
&
DC
Amperemeter
BF
Volmeter
Distortiometer
HF Volmeter
Wattmeter
-
Dummy
load
Osilloscope
FM linear detector
Load 8
Ω
AF generator Sinad meter
Conditions of Measurements on HF Generator
Reception
AM mode: Level - 107 dBm Frequency 1 KHz with 60% of modulation.
FM mode: Level - 107 dBm Frequency 1 KHz with 1,2KHz of deviation.
USB/LSB mode: Level - 107 dBm
Transmission
Frequency1,25 KHz 30mV AM/FM
Frequency two tones 0,4 KHz 30mV & 2,5KHz 30mV