ALIGNMENT RECEIVER
1 - Alignment procedure(13,2V;configuration”EU”)
STEP
CONDITION
ADJUSTMENT
REMARKS OF ADJUSTMENT
1
FM(EU)
Channel 20
Middle volume level.
No squelch active
NB/ANL/HICUT OFF
L19
Connect HF generator(27,205MHz)
to jack antenna adjusted at
(–47dBm 1KHz mod 1,2Khz
déviation).
Connect DC voltmeter to TP1 and
adjust L19 to reach 3 ± 0,1V
2
AM(EU)
Channel 20
Middle volume level.
Squelch control CW
NB/ANL/HICUT OFF
RT3
Connect HF generator(27,205MHz)
to jack antenna adjusted at
(–47dBm 1KHz mod
60%modulation).
Adjust RT3 CW direction so that the
signal is audible.
3
AM(EU)
Channel 20
Middle volume level.
Squelch control CCW
(ASC ON)
NB/ANL/HICUT OFF
RT1
Connect HF generator(27,205MHz)
to jack antenna adjusted at
( –111dBm without modulation).
Adjust RT1 CW direction so that the
signal is no longer audible.
4
USB(EU)
Channel 20
Middle volume level.
Squelch control CW
NB/ANL/HICUT OFF
RT2
Connect HF generator(27,206MHz)
to jack antenna adjusted at
(–47dBm without modulation).
Adjust RT2 CW direction so that the
signal is audible.
Summary of Contents for GRANT II PREMIUM
Page 1: ...GRANT II PREMIUM SERVICE MANUAL...
Page 11: ...TP 303 TP 302 TP 301 L 304 RT 302 L 307 L 305 L 306 ALIGNMENT VCO PLL...
Page 16: ...ALIGNMENT RECEIVER TP 1 L 19 RT 1 RT 3 RT2...
Page 17: ...GRANTII PREMIUM BLOC DIAGRAM...
Page 19: ...GRANTII PREMIUM SCHEMATIC DIAGRAM...
Page 20: ...ASC ASC IN ASC OUT RT 1 PRE...
Page 22: ...PRE...
Page 23: ...PRE...
Page 24: ...PRE...
Page 25: ...GRANTII PREMIUM COMPONENT LAYOUT...
Page 26: ...PRE...
Page 27: ...PRE...
Page 28: ...PRE...
Page 29: ...PRE...