ATTErY
1,2ah 12v
code aCG9511
s
OLAr AMPLIfIEr
Interface for 50W solar panels.
code aCG9125
M
ETALLIC MAss DETECTOr
to open with vehicles
1 channel - 230 vac
code aCG9060
1 channel - 12÷24 vac/dc
code aCG9063
2 channels - 12÷24 vac/dc
code aCG9064
L
OOP PrE-AssEMBLED
6 m - perimeter 2 x 1 + 15 m of cable
code aCG9067
10 m - perimeter 3 x 2 + 15 m of cable
code aCG9068
B
ATTErY CHArGE CArD
the time for the complete recharge of 12vdc 1,2ah batteries (n°
2 pieces connected in series, optional cod. aCG9511), at the first
installation is of 24 hours, with a charge current of 0,03a.
BATTErY sTATE sIGNALLING PILOT LIGHT fEEDIN
(TErMINALs 3-11)
In case the network tension lacks and the emergency battery is
operated, this pilot light switches on thus signalling the network lack,
and it starts lightening only when the battery is discharged. When the
pilot light lightens, the gearcase is no longer operative.
only when the network tension is back, the pilot light switches off and
all controls are restored. (obviously the battery will only recharge in
the presence of the network tension).
N.B.: IN CAsE WE EXCEED WITH THE PILOT LIGHTs, THE
LOGIC Of THE GEArCAsE WILL rEsULT DAMAGED WITH
A POssIBLE BLOCK Of THE OPErATIONs.
fUNCTIONING WITH BLACK OUT
If a battery is connected to the gearcase, with lack of network tension
the battery state pilot light switches on thus signalling the functioning
with battery. the functioning of the barrier is ensured until a charge
level of about 20v, after which there will be a signal given by the
recharge card to the microprocessor which blocks the barrier and
makes the battery state pilot light lighten. When the network tension is
back, the recharge card will start recharging the battery.
You just need pressing the remote control (or the opening button
or the step by step button) to open the barrier. once the barrier will
be open, give a closing command or wait the pause time before the
automatic closing. the barrier starts closing. When it is closed, the
normal functions will be restored.
If no battery is connected to the gearcase, there is no particular
procedure to follow. When the network tension is back, it is sufficient
to press the remote control, the opening button or the step by step
button to open the barrier. When the barrier is open, give a closing
command or wait the pause time before the automatic closing. the
barrier starts closing.
When it is closed, the normal functions will be restored.
During the realignment the securities are active.
code aCG4661
SUn 2CH
code aCG6052
SUn 4CH
code aCG6054
SUn CLone 2CH code aCG6056
SUn CLone 4CH code aCG6058