background image

 

                                                      PSPS40 / PSPT40   

.

 

4.

4.

4.

4.

 

OPERATIONS 

OPERATIONS 

OPERATIONS 

OPERATIONS      

 

Normal Weighing Mode

Normal Weighing Mode

Normal Weighing Mode

Normal Weighing Mode    

1.

 

Place the scale on a flat, stable surface. Level the scale using the leveling bubble at the lower left side of the display. 

2.

 

With the weighing platter empty, turn on power switch (located underneath on the right-hand side of the scale). Due 
to the high resolution of this scale, allow 10 minutes for the scale to warm up before use for optimum results. 

3.

 

Press the ON/OFF key to power on the scale. The self-check will run and the scale will display a zero reading. The 
scale is now ready for weighing. 
Note: If the scale does not zero, an error code will be displayed. See Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting to resolve.   

4.

 

To change the weighing unit of measure, press the Unit key to toggle between kg, lb or oz. 

5.

 

Set the tare weight if desired.   

6.

 

Place objects on the scale platter and read the weight on the indicator. 

7.

 

When finished weighing, press the ON/OFF key for 4 seconds to power off the scale. 

 

ZERO function

ZERO function

ZERO function

ZERO function    

1.    Under the normal weighing mode, press Zero key to set the scale to zero point when the scale reading is stable 
(the   
      weighing unit light without shining). 
2.    When under the tare mode, ZERO key is invalid. 
      Note: If the scale cannot be zeroed, an error code will be displayed. See Troubleshooting

Troubleshooting

Troubleshooting

Troubleshooting to resolve. 

 

Setting the Tare 

Setting the Tare 

Setting the Tare 

Setting the Tare Weight

Weight

Weight

Weight    

This scale allows for both a manually entered pre-set tare weight, as well as a “weighed” tare weight.   
1.

1.

1.

1.

 

To enter a weighed tare: 

To enter a weighed tare: 

To enter a weighed tare: 

To enter a weighed tare:      

a.

 

Place an empty container on the platter and press the Tare key.    The display will return to zero, eliminating 
the weight of the container. The Zero

Zero

Zero

Zero light will go off and the Tare

Tare

Tare

Tare light will be lit. 

Note

Note

Note

Note: The gross weight must be positive to enter a weighed tare. 

b.

 

To clear the weighed tare, remove all weight from the scale. The display will show a negative weight. Press 
the TARE key to return the display to zero, eliminating the weight of the container. The Tare

Tare

Tare

Tare light will go off 

and the Zero

Zero

Zero

Zero light will be lit.   

2.

2.

2.

2.

 

To 

To 

To 

To manually enter a known tare:

manually enter a known tare:

manually enter a known tare:

manually enter a known tare:    

a.

 

Use the number keys to input the tare weight. Your entry will be displayed in the “WEIGHT” display window. 
Then press the Tare key to confirm or press the ON/OFF key to exit and not confirm. 
Example

Example

Example

Example: With the platter empty, entering 100g and pressing the Tare key will display ““““

” kg. 

b.

 

To recall the previously stored tare weight, press the RC.PLU key. Press the ON/OFF key to return to 
weighing. 
Note

Note

Note

Note: The previously stored tare weight can only be recalled with the RC.PLU key when in tare setting 
mode. 

c.

 

To clear the manually entered tare weight, (enter “0” and) press the Tare key to confirm. 

d.

 

If unit price is in un-saved mode, the tare weight and unit price will be auto cleared after transaction and 
objects being moved. 

    

    

Summary of Contents for PSPS40

Page 1: ...PSPS40 PSPT40 PSPS40 PSPT40 PSPS40 PSPT40 PSPS40 PSPT40 User Technical Manual Contents subject to change without notice Version 1 0 04 2021...

Page 2: ...Auto Auto off time setting off time setting off time setting off time setting 10 7 7 7 7 Display A D inner code and working voltage Display A D inner code and working voltage Display A D inner code an...

Page 3: ...Do not operate near cell phones radios computers or other electronic devices that emit radio frequencies that may cause unstable readings 1 2 Specifications Model PSPS06 PSPT06 PSPS15 PSPT15 PSPS30 PS...

Page 4: ...tter size LxD 288x210 2 2 2 2 Unpacking and setup Unpacking and setup Unpacking and setup Unpacking and setup Take out the scale from the box and place it on a firm level surface Avoid locations with...

Page 5: ...Connect the column to the base and tighten them together with the hexagon socket head cap screws 3 Place the connector in the bracket put on the cover and fix it with tapping screws 4 Installation is...

Page 6: ...lb lb oz oz oz oz Weight unit indicator UNIT PRICE UNIT PRICE UNIT PRICE UNIT PRICE Unit price display window kg kg kg kg lb lb lb lb oz oz oz oz Unit price per kg lb oz indicator TOTAL PRICE TOTAL P...

Page 7: ...data when has RS232 hardware UNIT UNIT UNIT UNIT Switch the unit of price and weight ON OFF ON OFF ON OFF ON OFF When the display is off press O O O ON N N N O O O OFF FF FF FF key to turn on the scal...

Page 8: ...ts digit segments digit segments digit segments digit Symbol Symbol Symbol Symbol 7 7 7 7 segments di segments di segments di segments digit git git git Symbol Symbol Symbol Symbol 7 7 7 7 segments di...

Page 9: ...e Tare Setting the Tare Weight Weight Weight Weight This scale allows for both a manually entered pre set tare weight as well as a weighed tare weight 1 1 1 1 To enter a weighed tare To enter a weighe...

Page 10: ...SB serial port according to the set method Print format are as follows 1 1 1 1 Print Out format in HOST mode Print Out format in HOST mode Print Out format in HOST mode Print Out format in HOST mode I...

Page 11: ...to input ingredients only available when 232 out is set to PRTd60 the UNIT PRICE window shows the last six characters of the ingredients 6 Use numerical keys and CLEAR key to input the ingredients th...

Page 12: ...and press ENTER key for confirmation Press ON OFF key to exit this mode and the scale will automatically reset x 1 back light is always off 2 back light is always on 3 Backlight On Request backlight...

Page 13: ...d6 Nd6 use ENTER key for confirmation to go to the next step or ON OFF key to exit this mode 3 Then the WEIGHT window will show Setup the UNIT PRICE window will show 232 bPS RS232 band rate bit per se...

Page 14: ...the input and go to the next step or use ON OFF key to exit this mode Then the UNIT PRICE window will disPSPT40ay B PRT FT format of barcode for printing the TOTAL PRICE WINDOW will show the barcode U...

Page 15: ...fer to Prin Prin Prin Print out format when OS t out format when OS t out format when OS t out format when OS 2130D 2130D 2130D 2130D printer is connected printer is connected printer is connected pri...

Page 16: ...rst line the UNIT PRICE window and the TOTAL PRICE window disPSPT40ay the last 12 char of the business name 3 Use numerical keys and CLEAR key to input the business name the max length of the business...

Page 17: ...s and Clear to input X offset 0 255 press Enter key to confirm the input and go to the next step 4 The WEIGHT window disPSPT40ays SETUP the UNIT PRICE window disPSPT40ays ORG Y Origin Y and the TOTAL...

Page 18: ...ally until connect with the scale Manual connection is also available by use Serial Set in Serial menu 4 Press Open or open file button in File menu it will first remind you whether to save the curren...

Page 19: ...name it means it s downloading the store name If it disPSPT40ays Downloading Mxx it means it s downloading the information of M1 M9 direct unit price If it disPSPT40ays Downloading No xxx it means it...

Page 20: ...PSPT40oading the information of M1 M9 if it disPSPT40ays uPSPT40oading No xxx it means it is uPSPT40oading the information of PSPT40U1 265 UPSPT40oad successful will be disPSPT40ayed after uPSPT40oadi...

Page 21: ...he disPSPT40ay of the WEIGHT window remains the same the UNIT PRICE window disPSPT40ays LoAd which means the scale is ready to calibrate the standard weight The disPSPT40ay of the TOTAL PRICE and WEIG...

Page 22: ...ing of some disPSPT40 PSPT40 PSPT40 PSPT40ayed symbols ayed symbols ayed symbols ayed symbols Weight signal is too large No proper data can be disPSPT40ayed Weight signal is too small Zero point is ov...

Page 23: ...go to 0 Something wrong with the keys or faulty PCB board or Load cell Check the key button RePSPT40ace the PCB or load cell Missing segment or marks on LCD LCD connect pin broken RePSPT40ace LCD Powe...

Page 24: ...ust proof wash Clear the objects RePSPT40ace the load cell Calibration can t be finished The inner code at zero point is too small or too big not enough with the full capacity inner code not stable th...

Reviews: