background image

5

Make sure the surroundings of the sink are cooled  before mounting  the 
faucet  to the sink after drilling and remove all sharp edges. 

Step 3

Step 4

Determine desired  location  for  the RO faucet on your sink and place 
a piece of masking tape on over where the hole is  to be drilled.  Mark 
the center of the hole on the tape.

Step 1

Using a variable speed drill set on the slowest speed, drill a 

1

/

8

“ pilot 

hole through both porcelain and metal casing of sink at the marked 
center of  the desired location. Use lubricating oil or liquid soap to keep 
the drill bit  cool (If drill bit gets hot it may cause the porcelain to crack 
or chip). 

Using a 1/2” hole saw, proceed to drill the large hole.  Keep drill speed 
on  the  slowest speed and use lubricating oil or liquid soap to keep the 
hole saw cool during cutting.

Step 2

Drill a Hole for the Faucet in a Porcelain Sink

Punch a Hole for the Faucet in a Stainless Steel Sink   

Drill a 

¼

” pilot hole.  Use a 

1

/

2

” Hole Punch and an adjustable wrench 

to punch the hole in the sink.

Step 5

The faucet can now be installed.

If  mounting faucet to a Stainless Steel Sink you will need a 1/2”
minimum hole punch.  The  faucet opening should be centered 
between  the back splash and the edge of the sink, ideally on the 
same side as the vertical drain pipe.

Note:

Note:

Most sinks are pre drilled with 1 ½” or 1 ¼” diameter hole that you can use for your 
RO faucet. (If you are already using it for a sprayer or soap  dispenser, see step 1)

Porcelain sinks are extremely hard and can crack or chip easily.  
Use extreme caution when drilling.  Premier accepts no responsibility for 
damage resulting from the installation of faucet.

Not recommended for use on homes equipped with tankless water heaters. Contact Premier for
specifi c details regarding this unit and tankless water heaters.
System was tested in a laboratory setting utilizing a hot water heater of 40 gallons set at 120º F.
Performance may vary if your heater is smaller than 40 gallons or set above 120º F, contact the
manufacturer for additional details.
System should not be used on homes equipped with a backfl ow prevention on the hot water heater.
This device is 100% effi cient, as no water is lost to drain in the production of the RO water.

***IMPORTANT NOTICE***

Summary of Contents for ZRO-4

Page 1: ...ameters may lead to the product s failure Save manual for future reference Model ZRO 4 ZERO WASTE REVERSE OSMOSIS SYSTEM Premier Inc 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www PremierH2o com Fax 623 866 5666 199229 Manual Date 02 22 2016 System is in compliance with the Uniform Plumbing Code UPC International Plumbing Code IPC and IGC 159 2000A ...

Page 2: ... alone Your system is a four stage RO which is based upon separate treatment segments within the one complete water filtration system These stages are as follows Stage 1 Sediment filter recommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your ...

Page 3: ...ill a Hole for the Faucet in a Porcelain Sink 5 Punch a Hole for the Faucet in a Stainless Steel Sink 5 Installation of Faucet 6 Connect Blue Tube from the RO to the Fuacet 6 Adapt a Valve Installation 7 Connect the Green and Black Tubing 7 Mounting the RO Module 7 Tank Ball Valve Installation 7 Blue Tube Connection From the RO Module to TANK 8 Start up Instructions 8 6 Month System Maintenance 9 ...

Page 4: ...comply with State and local plumbing regulations This system is to be installed to treat cold water only Copper Tubing Reverse Osmosis water should not be run through copper tubing as the purity of the water will leach copper causing an objectional taste in water and pin holes may form in the tubing Premier supplies speciality filters part number 107008 that can be used if copper tubing follows th...

Page 5: ...ep 5 The faucet can now be installed If mounting faucet to a Stainless Steel Sink you will need a 1 2 minimum hole punch The faucet opening should be centered between the back splash and the edge of the sink ideally on the same side as the vertical drain pipe Note Note Most sinks are pre drilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer...

Page 6: ...ghten brass nut securely Connect Blue Tube from the RO to the Faucet Step 9 Locate the blue 1 4 tube attached to the RO module labeled Faucet Remove a brass nut plastic sleeve and brass insert from the parts bag To assemble place the brass nut on the blue tube first then the sleeve small tapered end of sleeve must point to the end of tube and then push the brass insert all the way into the end of ...

Page 7: ...ubing attached to the RO system Insert the open end of the green 1 4 tube into the open 1 4 quick connect fitting on the COLD water feed adapta a valve making sure the tube is pushed in all the way to the tube stop Repeat the procedure to connect black tubing from the RO module to the hot water return adapt a valve Mounting the RO Module Determine the best location for the RO Module to be mounted ...

Page 8: ...drip Then close the faucet The tank will take approximately 4 hours to fill Note If no water comes out of the RO faucet after a few minutes check the power outlet It is possible that the power outlet you used for the RO unit is controlled by the garbage disposal switch To test Unplug the garbage disposal and flip the garbage disposal switch to on If the RO pump turns on and water starts to drip ou...

Page 9: ...d soap solution and rinse with water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re installing the filter bowls back on to the system check O rings to make sure they are still in place Caution Insert a new sediment filter cloth like appearance into the 1st fi...

Page 10: ...ressurize Turn on the RO faucet and let the water run for 30 seconds Turn off the RO faucet and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Unplug the Power Transformer Turn off the incoming water supply to the system by turning the adapt a valve clockwise until it stops Keep the RO faucet open until the storage tank is completely drained Ope...

Page 11: ...on Periodic inspection and following proper system maintenance is critical for continued performance Loosen Membrane Maintenance Use a 5 8 wrench to remove the Green Tube fitting on the left side of the horizontal membrane housing end with one elbow Step 1 Step 2 Step 3 Step 4 Step 5 Note Step 1 Turn off the incoming cold water supply to the RO at the adapt a valves and unplug the power transforme...

Page 12: ...leaks at the top after Damaged Dry O ring Lubricate with water soluble lubricant or replace changing the filters O ring as necessary Do not use Vaseline or other petroleum based lubricants Pump constantly running Electrical fault Call for technical support Faucet left on Close faucet and let tank fill for 2 to 3 hours Plugged pre filters Replace filters 12 Once all water in the tank is purged chec...

Page 13: ...rd Step 2 Lever will slide forward and completely off of the faucet base Step 3 Small brass tee can be turned 1 2 turn counterclockwise to adjust the tension on the black lever This adjustment may be necessary to stop slow drips from tip of faucet You may need to repeat the process until the faucet does not drip Brass tee must always end up facing across body of faucet in order to slide black leve...

Page 14: ... mg L 0 5 mg L 93 9 7 49 50psi 0 7 8 0 10 1 5 Lead Reduction 0 15 mg L 0 002 mg L 98 6 7 49 50psi 0 003 0 15 10 0 010 Radium 226 228 25 pCi L 5 pCi L 80 0 7 24 50psi 5 pCi L 25pCiL 10 5 pCi L Selenium 0 10 0 008 92 0 50psi 0 011 0 10 10 0 05 TDS 752 27 96 4 7 84 50psi 34 mg L 750 40mg L 187 Turbidity 10 2 mg L 0 26 mg L 97 5 0 83 11 1 NTU 0 5 NTU RECOVERY 16 75 GALLONS 24 8 GPD EFFICIENCY 12 0 Eff...

Page 15: ...t convert all the trivalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water system This Premier reverse osmosis system is designed to remove pentavalent arsenic It will not convert trivalent arsenic to pentavalent arsenic Under laboratory standard testing conditions this system reduced 0 30 mg L pp...

Page 16: ...16 ...

Page 17: ...10115 BLACK TUBING 1 4 X 3 1 2 45 610117 BLACK TUBING 1 4 X 4 46 610113 BLUE TUBING 1 4 X 4 47 610109 GREEN TUBING 1 4 X 4 Item Part Description 1 116023 FAUCET AG CHROME 2 134018 VALVE BALL PLAS ELB 4 119007 TANK PRESS 3 GAL WHITE 5 119028 TANK STAND 6 125017 CON PL 1 4C X 1 4M 7 100017 GAC IL 10 1 4F 8 125064 TEE MALE RUN 1 4 X 1 4 M 9 152032 SWITCH PRESSURE 60 PSI TSO 10 164010 CLIP DOUBLE MEM ...

Page 18: ... Monitored 57 95 each 116093 Brushed Nickel Monitored 62 95 each Other Products from Premier Premier offers a filter change kit which includes all replacement filters needed Call 1 800 752 5582 or buy on line at www PremierH2o com 1 4 inch connection kit includes 30 feet of 3 8 tubing ball valve and fittings Part No 500010 16 95 ea Premier Hot Water Recirculation System Bring convenience and savin...

Page 19: ... Sediment Filter and a Carbon Block Filter Part No 560032 24 95 each Using only the available energy from the brine water otherwise lost to the drain the pump forces product water into the storage tank This process effectively reduces membrane back pressure to less than 5 psi and allows the membrane to maximize its use of the available feed pressure PERMEATE PUMP KIT For Standard RO Systems Non Ze...

Page 20: ...ivel Ball Extension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray Soft Touch Adjustment Pads Anti Scaling Spray Nozzle High Strength Housing Triple Plated Finish Cartridge Life Rating 6 months Part No 107098 White Chrome 39 95 Part No 107080...

Page 21: ... enter your information XXXXX XXXXXX Premier Inc is concerned for the safety of your personal information Premier collects personal information when you register with Premier This information is stored in our data base and we do not rent sell or share personal information with other people or nonaffiliated companies We reserve the right to send you certain types of communications such as direct ma...

Page 22: ... USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By SELF Plumbing Professional Where Purchased ____________ Model Number _______________________ Serial Number ____ __________ Iowa Department of Public Health Sales in Iowa require this to be completed s...

Page 23: ...RVICE RECORD DATE OF PURCHASE DATE OF INSTALL INSTALLED BY SERIAL NO NAME Date of 6 mos 6 mos 1 yr 2 5 yrs OTHER Maintenance 1st stage 2nd stage Final Filter TFM Memb Sediment Carbon Block Carbon NOTES 23 ...

Page 24: ...s per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This warranty does not cover any equipment that is relocated from the site of its original installation This warranty...

Reviews: