Premier Mounts LPFM5080 Installation Instructions Manual Download Page 2

Page 2  

 

 

 

 

 

 

 

 

                    Installation Instructions

Table of Contents

Warning Statements

LPFM5080

PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS SHOULD BE READ AND 
COMPLETELY UNDERSTOOD. THE INSTALLATION INSTRUCTIONS MUST BE READ TO PREVENT PERSONAL INJURY AND 
PROPERTY DAMAGE. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE 
REFERENCE.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS 
PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED 
ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, 
ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER 
RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
THE SURFACE MUST BE CAPABLE OF SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT, THE 
MOUNTING STRUCTURE MUST BE REINFORCED. THE MAXIMUM WEIGHT THAT CAN BE USED WITH THIS PRODUCT 
IS 300LBS. PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE 
INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL 
INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY 
GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

Contact Premier Mounts with any questions 
(800) 368-9700
[email protected]

At least two qualified people should perform the assembly procedure. Injury and/or damage can result from dropping or mishandling the 
flat panel.

If mounting to studs, make sure that the mounting screws are anchored into the center of the studs. Use of an edge-to-edge stud finder is 
recommended.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there are no electrical wires 
in wall. Cutting/drilling into an electrical line may cause serious injury.
Make sure there are no water lines inside the wall where the mount is to be located. Cutting/drilling into a water line may cause severe water 
damage to the mounting surface.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.

Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.

Warning 

Statements 

         2

Parts 

List           3

Installation 

Tools 

          3

Hardware 

Pack 

          4

Features 

           5

Wood 

Stud 

Installation 

         6

Concrete 

Surface 

Installation 

        7

Determining 

the 

Mounting 

Hardware        9

Universal 

Spacer 

Installation 

        9

Universal 

Washer 

Installation 

        10

Mounting 

Bracket 

Installation 

        11

Attaching 

the 

Display 

to 

the 

Wall 

Plate 

       12

Securing 

the 

Flat 

Panel 

         12

Technical 

Specifications 

         13

Warranty           14

Summary of Contents for LPFM5080

Page 1: ...East Miraloma Avenue Anaheim CA 92806 USA USA and Canada Phone 800 368 9700 Fax 800 832 4888 EUROPE Swallow House Shilton Industrial Estate Shilton Coventry England CV79JY Phone 44 0 2476 614700 Fax 4...

Page 2: ...SE PROPER SAFETY GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY Contact Premier Mounts with any questions 800 368 9700 techsupport mounts com At least two qualified people should...

Page 3: ...ing installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts 800 368 9700 Installation Tools not supplied Wall Plate Qty 1 Safety Security Screws...

Page 4: ...m Qty 6 M6 x 30mm Qty 6 M6 x 25mm Qty 6 M6 x 16mm Qty 6 M5 x 30mm Qty 6 M5 x 25mm Qty 6 M5 x 16mm Qty 6 M8 x 70mm Qty 4 M8 x 45mm Qty 6 M8 x 30mm Qty 6 M8 x 25mm Qty 6 M8 x 16mm Qty 6 M10 x 30mm Qty 6...

Page 5: ...ofile Design Holds the flat panel less than 1 from the wall Cable Electrical Cut Out Large cut outs on the wall plate allow for easy cable access and power distribution Universal Spacers Uniquely desi...

Page 6: ...ing a 1 4 drill bit drill a pilot hole at the first aligned and marked location Step 5 Insert one 1 5 16 x 3 lag bolt and washer into the mounting hole and tighten see WARNING below using a 1 2 socket...

Page 7: ...tep 1 Place the wall plate into position against the wall keeping it level Step 2 Mark off six holes to be used for securing the mount and place the wall plate aside Level Mark Concrete anchors are no...

Page 8: ...a hammer to lightly tap each anchor into place so that they are flush with the wall Drill Step 6 Once all of the anchors are in place move the wall plate back into position Step 7 Attach nuts and was...

Page 9: ...th Indicator When using the universal spacers in the installation make sure to account for the appropriate spacing depth when measuring with the thread depth indicator Using the universal spacers will...

Page 10: ...res EXAMPLE If your flat panel uses M8 screws use the M8 mounting points Universal Washer Installation Pre install the mounting screws spacers and washers Once mounted push down to eliminate movement...

Page 11: ...readed mounting points that are located on the back of the flat panel Step 2 Determine the correct screw length by carefully inserting a straw or toothpick and mark the depth of the mounting point Ste...

Page 12: ...his kit includes various screws of different diameters and lengths Attaching the Display to the Wall Plate The number of mounting points will vary between manufacturers Select the spacer that is close...

Page 13: ...tighten the safety security screws with a Phillips head screw driver please see inset to the right Safety Security Screw SecurityScrew Tab Do not release the flat panel until the top and bottom hooks...

Page 14: ...R A PARTICULAR PURPOSE PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUD ING BUT NOT LIMITED TO INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOV ING AND REPLACING...

Reviews: