Safety Curtain Adjustment
If the Safety Curtain displays a red light when the beam is not broken the curtain requires
adjustment.
To adjust the Safety Curtain:
1.
Loosen the M3 socket head screw on top/bottom of the upper and lower safety
curtain brackets on either or both sides of the Coiler cage.
2.
Adjust the Safety Curtain angle by rotating the loosened Safety Curtain until the left
hand Safety curtain displays three green lights and one blue light indicating that the
safety curtain is working properly.
3.
Re-tighten the M3 screws and check that the three green lights and one blue light
are illuminated, with the red light coming on only when the beam is broken.
Red Light indicates curtain requires adjustment
Loosen the socket screws
3 green lights and 1 blue light indicates curtain is
working correctly
Tighten the socket screws