3.6.1
RAMP Setting
When MAIN page displays on the screen, users can press
to enter into RAMP
page.
Figure 3.33 Ramp setting page
The descriptions for the items and icons in the above figure are given as follows.
Press the corresponding value on item
of each ramp
set to set start and end output voltage/frequency and dwell time. When setup is
completed, press
to confirm. To edit an entry, Press
to clears all digits
or press
to delete the last digit for editing.
Figure 3.34 Start/End output voltage and frequency settings
Notice
In PGM mode, the RAMP output voltage setting will be fixed to the high level for a
wide range setting.