AFV
+
Series High Power Programmable AC Power Supply
6-118
6.10.6
Gradual Mode
Setup for Gradual Mode
:
FUNC GRAD\r\n
Setup Group1 Output Voltage
:
SOUR:GRAD:VOLT 1,110.0,220.0\r\n
Setup Group1 Output Frequency
:
SOUR:GRAD:FREQ 1,50.0,60.0\r\n
Setup Group1 Running Time Interval
:
Mode 1
:
0 Hour, 0 Minute, 10.0 Second
:
SOUR:GRAD:TIME 1,0:0:100\r\n
Mode 2
:
0 Hour, 0 Minute, 10.00 Second
:
SOUR:GRAD:TIME 1,0:0:1000\r\n
……
Setup Group12 Output Voltage
:
SOUR:GRAD:VOLT 12,110.0,220.0\r\n
Setup Group12 Output Frequency
:
SOUR:GRAD:FREQ 12,50.0,60.0\r\n
Setup Group12 Running Time Interval
:
SOUR:GRAD:TIME 12,00:00:10\r\n
Mode 1
:
0 Hour, 0 Minute, 10.0 Second
:
SOUR:GRAD:TIME 24,0:0:100\r\n
Mode 2
:
0 Hour, 0 Minute, 10.00 Second
:
SOUR:GRAD:TIME 24,0:0:1000\r\n
Setup Gradual Mode Start group/End group/Cycles times
:
SOUR:GRAD:PCYC
1,12,10\r\n
Setup All Gradual Data
:
SOUR:GRAD:LOAD\r\n
(
Optional
)
Start to Output
:
OUTP 1\r\n
6.10.7
Three-Phase Independent Output Mode
Setup Function Mode
:
FUNC THR\r\n
Setup for Three-Phase Output Voltage Mode
:
INST:COUP 1\r\n
Setup High/Low Level
:
SOUR:VOLT:RANG 1\r\n
Setup Output Voltage
:
SOUR:VOLT 220.0,220.0,110.0\r\n
Setup Output Frequency
:
SOUR:FREQ 50.0\r\n
Start to Output
:
OUTP 1\r\n