2.6
Remote Sensing Connection (Optional)
The AFV+ series supports optional Remote Sensing function, monitoring the voltage
at the load instead of the output terminals of the product, ensuring the load receives
the product programming voltage by automatically compensating for the output
voltage drop due to cable resistance.
Remote Sensing Connection with the function disabled:
When the power supply and the load are close enough, Remote Sensing function can
be disabled. Please refer to Figure 2.12 for Remote Sensing Connection (not used).
Figure 2.12 Remote Sensing Connection (not used)
Remote Sensing Connection with the function enabled:
When the power supply and the load have certain distance and need long connecting
cable, Remote Sensing can be enabled for compensating the output voltage drop due
to cable resistance. Please refer to Figure 2.13 for Remote Sensing Connection (in
use). Remove the original shorting leads, and connect the remote sensing connector
SU\SV\SW\SN to the corresponding terminals U\V\W\N at the load, as shown in
Figure.
.