Precor PVS Installation Manual Download Page 9

Rewire the AMT

Remove the front and side access covers to provide sufficient space to install the

console cables.

IMPORTANT

Before continuing with the following procedure, be sure to remove any ties or

other materials that hold the side arms in place before the supports are installed.

To thread the new cables through the equipment:

2

Step

Procedure
Lift the moisture seal upward and remove it from the center column.

Extend a finger through the moisture seal opening and under the

front edge of the top cover on one side. While pressing upward on

the top cover, use the heel of your palm to tap gently below its front

edge and release it. Repeat this step to release the other side of the

top cover.
While holding the front edge of the top cover up, use the palm of

your other hand to tap gently just below the cover's back edge. Lift

the cover up and out of the way.
Remove the two screws at the bottom corners of the front cover.

Gently press in on each of the side covers, just behind the front edge

and about 8 inches from the bottom, while pulling the front cover

assembly forward to disengage it. Move the front cover assembly

forward and slightly upward to remove it.

Note Each side cover has a small triangular mark to show you where

to press.

N/A

Thread the PVS power and television cables through the center

column and guide them through the opening at the bottom.

Important The cables must be secured in the cable retainers attached to

the frame. They must then pass through the square opening in the jack

panel.
Guide the arm openings in the front cover around the arms of the

AMT, taking care that the tabs at the bottom corners of both

openings are inside the two side covers, then guide the front cover

until the latches on the side covers click into place. Reattach the two

screws at the bottom corners of the front cover. Fully tighten the

screws.

N/A

Important In the following step, do not apply excessive force to seat the

cover.

Position the rear edge of the top cover so that the clips on the top

and back covers are engaged securely. Gently snap the front edge of

the top cover into place. Use the palm of your hand if necessary.

N/A

Wrap the moisture seal around the center column below the heart

rate sensor grips, then fit it into the top cover. Make sure that the

surfaces and edges of the moisture seal are flush with those on the

top cover.

 9

Summary of Contents for PVS

Page 1: ...Personal Viewing System PVS Installation Guide for the P31 Console ENGLISH...

Page 2: ...of its product design Any party contemplating the use of Precor product designs is hereby forewarned that Precor considers the unauthorized appropriation of its proprietary rights to be a very serious...

Page 3: ...2 Phillips screwdriver bit Hardware Kit The following fasteners and components are included in the hardware kit If your hardware kit is missing parts contact Precor Customer Support Hardware Hardware...

Page 4: ...ware Hardware name Quantity Tie wrap 1 Jack panel treadmills only 1 Charging cable 1 Ground wire 1 Television coax cable with 90 degree elbow adapter 1 PVS power cable 1 AC power cord based on region...

Page 5: ...ire the equipment you need the following new cables from the hardware kit Television coaxial cable Power cable disconnect the power cable from the AC adapter NOTE Tape the television and power cables...

Page 6: ...an arrow in the figure Route the cables down the cable channel in the upright support Pull the cables from the bottom of the right upright support and thread them across the base frame Secure them wit...

Page 7: ...r pops off Slide the front cover off Remove the two screws that secure the blank jack plate and set them aside Attach the following cables to both sides of the new jack plate A Communication cable B T...

Page 8: ...he bottom Remove the two screws that secure the blank jack plate on the front bottom cover Attach the following cables to both sides of the new jack plate A Communication cable B Television coax C Pow...

Page 9: ...rd to disengage it Move the front cover assembly forward and slightly upward to remove it Note Each side cover has a small triangular mark to show you where to press N A Thread the PVS power and telev...

Page 10: ...around the bolts that hold the center mast in place Feed the cables through the square opening in the jack panel using the communication cable s wire retaining feature then slide the jack panel back...

Page 11: ...uide the cover around the pedal crank then remove it Remove blank jack panel at base of bike and feed the cables down the mast The cables need to be threaded around the bolts that hold the center mast...

Page 12: ...onsole and feed the taped cable ends through the opening Continue to feed the cables down through the upright column Pull the cables out of the opening at the base of the column Note You may need to u...

Page 13: ...ong 5 16 x 3 inch SHCS To attach the back plate IMPORTANT DO NOT stretch crimp or damage the cables Cables damaged by improper installation are not covered by the Precor Limited Warranty 1 Insert the...

Page 14: ...Precor Limited Warranty To route the cables 1 Tip the console forward and hold it in place 2 Pass all cables through the opening just above the console mount hook Use the following table to plug the c...

Page 15: ...tch crimp or damage the cable Cables damaged by improper installation will not be covered by the Limited Warranty To rewire a blank chin 1 Remove existing chin from the console 2 Slide heart rate boar...

Page 16: ...able to the PVS in an upcoming step To attach cables and the console chin 1 Pull the audio cable power cable and grounding wire through the hole at the bottom of the console 2 Press the tab to remove...

Page 17: ...d 5 32 inch hex wrench is helpful to complete this step 3 Carefully position the console access cover around the PVS mounting bracket and snap it into place NOTE If the cover does not easily snap into...

Page 18: ...using four black screws from the hardware kit 3 If required reattach the 90 degree elbow fitting to the coax cable 4 Plug the cables into the bottom of the PVS Key Cable Power Audio Television coax 5...

Page 19: ...1 1 solution total concentration between 45 and 50 to a typical full strength solution normally 91 to 99 You may also use commercially available isopropyl alcohol solutions within this range or flat...

Page 20: ...PVS Installation Guide for P31 Consoles P N 305262 101 ENU 2019 Precor Incorporated 14 February 2019...

Reviews: