a. If not, go the Handheld HHHR troubleshooting procedure to fix the problem.
b. If yes, continue procedure.
2. Verify the wireless heart rate function using a known good chest strap transmitter or
test transmitter. If the heart rate reading is erratic, incorrect, or absent, continue
troubleshooting.
Note
: It may be necessary to temporarily move closer to the console to allow the
receiver to acquire the heart rate transmitter signal.
3. Identify possible sources of wireless signals that are transmitting near the machine
that could cause HHHR transmitter signal interference. Possible types of products
that can cause signal interference include:
l
Wi-Fi
1
Network Routers
l
Cordless Telephones
l
Cell Phones
l
Electronic Dog Fences
l
Garage Door Remotes
l
Florescent light ballasts
4. Power OFF any possible sources of signal interference while using the wireless
HHHR chest transmitter and note if the problem is fixed.
a. If yes, either do not use that device or move it far enough away from the
machine so that it does not interfere with the wireless HHHR transmitter.
b. If NO, continue procedure.
5. If the preceding procedures do not correct the problem, replace the heart rate HHHR
PCA board.
See Also
"System Troubleshooting Procedures" on page 189
1
Wireless Fidelity - a term defined and Trademarked by the Wi-Fi Open Alliance. Wireless
LAN equipment carrying the Wi-Fi logo have been interoperability tested for compatibility
with one (or more) 802.11 standards, and certified by the Wi-Fi Alliance to be sold under the
Wi-Fi brand.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 209
7 Troubleshooting
System Troubleshooting Procedures