C762, C764, C764i Stairclimber
Page 34
Procedure 6.5 - Troubleshooting the Speed Sensor
Note:
If the stairclimber is unused for 30 seconds, power is removed from the magnets. The
stairclimber senses that it is being used by monitoring the speed sensor output.
1.
Set the circuit breaker in the “on” position and enter the manual program.
2.
Using a voltmeter, measure the voltage between the orange and brown wires on the speed
sensor. The voltage should be approximately 12 Vdc. If the voltage is 0 Vdc or very low, go
to step 4, otherwise continue with step 3.
3.
Using a voltmeter, measure the voltage between the blue and brown wires on the speed
sensor. Slowly rotate the disc assembly by hand, the voltage should alternate between
approximately 12 Vdc and 0.5 Vdc. If the voltage is good, skip to step 5.
4.
Perform the voltage measurements in steps 2 and 3 on the orange, blue and brown wires on
connector P2 of the lower board.
a.
If both voltages are good, check the wiring and connections between connector P2 of
the lower board and the speed sensor. If the wiring and connections are good, go to step
5.
b.
If the voltage in step 2 is 0 Vdc or very low, disconnect the P2 connector and recheck
the voltage on terminals 1 and 4 of P2 on the lower board. If the voltage is correct, re-
place the speed sensor. If the voltage is still 0 Vdc or very low, replace the lower PCA.
If you have performed all of the previous procedures and have been unable to locate the
problem, contact Precor Customer Support.
5.
At this point the voltages at the speed sensor and at the P2 connector of the lower board are
correct but a stepping rate is not displayed when the stairclimber is used. There are three
possible parts that could cause these symptoms. They are the lower PCA, lower ribbon
cable, upper ribbon cable and upper PCA. The easiest method of determining which part is
bad is to substitute a known good part. Substitute one part at a time and replace the original
part if the replacement does not correct the problem.
6.
If you have performed all of the previous procedures and are unable to locate the problem,
contact Precor Customer Support.
Summary of Contents for Cardio Theater Integrated Bracket C764i
Page 23: ...C762 C764 C764i Stairclimber Page 23 Diagram 5 3 Magnet Wiring ...
Page 61: ...C762 C764 C764i Stairclimber Page 61 Diagram 7 7 Magnet Wiring ...
Page 100: ...C762 C764 C764i Stairclimber Page 100 Wiring Diagram 8 1 C762 C764 120 Vac ...
Page 101: ...C762 C764 C764i Stairclimber Page 101 Block Diagram 8 2 C762 C764 120 Vac ...
Page 102: ...C762 C764 C764i Stairclimber Page 102 Wiring Diagram 8 3 C762 C764 240 Vac ...
Page 103: ...C762 C764 C764i Stairclimber Page 103 Block Diagram 8 4 C762 C764 240 Vac ...