Procedure 5.1 - Inspecting and Adjusting the Gaps Between
the Disk and the Magnet Assemblies
Procedure
1.
Remove the covers as described in Procedure 7.1.
WARNING
Before performing maintenance operations with the covers removed, review the Warning and
Caution statements listed in Section One, Things You Should Know.
2.
Press down the stairarm with one hand. With your other hand, grasp and pull the end of the
stairarm belt connected to the return spring. Release the stairarm. Remove the belt from the
pulley and belt idler (see Diagram 5.1).
Diagram 5.1 Removing a Stairarm Belt
3.
Place the .050 feeler gauge between the disk and the top coil on the right magnet assembly
Stairarm Belt