Installation Instructions

Before you Start

Prior to installing the Wireless WorkSight PreView sensor, take time to familiarize 

yourself with the installation instructions, theory of operation, and system 

components. Check the contents of the shipping package and verify the following 

items are included:

Sensor (1)

Sensor Interconnect Cable (1)

User Manual/Operating Instructions and drill template

Sensor Stainless Steel Mounting Hardware

 

1-1/4” x 10-24 Bolts, Hex Locking Nuts, and Washers (4)

Sensor Location

The Wireless WorkSight PreView sensor mounting location is integral to proper 

system operation. Ideally the sensor should be mounted on the rear center of 

the vehicle at roughly 36” (1M) +/- 12” (0.3M) above the ground. The sensor 

face should be perpendicular to the ground with the “PreView” graphic opening 

upward. Select a location that will provide some protection from impact and debris 

while allowing an unobstructed view of the target hazard area.

Important!

Before the Wireless WorkSight PreView sensor is permanently installed to the 

vehicle, verify that the selected mounting location provides a clear detection 

zone. Temporarily attach the sensor in the proposed mounting location, apply 

power to the system, and verify that nothing is being detected.

Sensor Mounting

1.  Select the appropriate sensor mounting location.

2.  The correct mounting configuration is with the sensor’s text in normal reading 

position.

3.  Using the drill template, scribe position marks through the holes. Drill 1/4” 

(6mm) holes centered at the marks.

4.  A 1-1/2” diameter clearance hole is required for the sensor connector and 

mating cable connector.

5.  Secure the sensor to the vehicle with the four supplied 10-24 UNC button 

head screws, washers and nuts or equivalent. Apply a maximum torque of 22 

inch pounds when securing the sensor.

Summary of Contents for Wireless PreView WorkSight WWS7220

Page 1: ...way Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 4901 APS Singapore Colombia Ch...

Page 2: ...e designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 3: ...4901 APS Singapore Colombia Chile Per Brasil CONTENTS Product Description Sensor Antenna Description Object Detection Capability Installation Instructions Before You Start Sensor Antenna Location Sen...

Page 4: ...ject detection system designed to alert vehicle operators to the presence of obstacles The system detects both moving and stationary objects in a pre defined coverage area and reports this information...

Page 5: ...ned signals to determine if an object has reflected any energy back to the sensor and reports this to the operator display The sensor is designed to process and report detections within of a second al...

Page 6: ...es an object reflects a certain amount of this energy back to the PreView sensor If the returned energy is of sufficient magnitude it is used to indicate object presence and determine the object s dis...

Page 7: ...APS USA 610 Gateway Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 4901 APS Singa...

Page 8: ...of the vehicle at roughly 36 1M 12 0 3M above the ground The sensor face should be perpendicular to the ground with the PreView graphic opening upward Select a location that will provide some protect...

Page 9: ...he display should be showing the Clear screen If the display is indicating a detection and there is no object in the machine s vicinity check for any objects on the machine which may be detected by th...

Page 10: ...System is intended for commercial use Proper installation of a back up aid requires a good understanding of truck electrical systems and procedures along with proficiency in the installation 7 Store...

Page 11: ...ion method A see the display manual verify reverse connection has 9 33V present For installation method B see the display manual verify sensor is powered and communicating Connection To Sensor Failed...

Page 12: ...Four 0 25 6 4mm diameter holes on 8 54 horizontal centers and 2 00 vertical centers Unit is supplied with 10 SS screws for mounting purposes Recommended torque is 22 inch lbs ELECTRICAL SPECIFICATION...

Page 13: ...S MANUFACTURERMAKESNOOTHERWARRANTIES EXPRESSED IMPLIED OR STATUTORY THE IMPLIED WARRANTIES FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUC...

Page 14: ...Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 4901 APS Singapore Colombia Chile Per Brasil PreView Configuration Options Custom System Configurations Thanks to th...

Page 15: ...supply com APS USA 610 Gateway Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 490...

Page 16: ...supply com APS USA 610 Gateway Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 490...

Reviews: