COLLISION ALERT SYSTEMS
APS-SUPPLY.COM
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
Unit 1, 72 Kent Way
Malaga WA 6090 Australia
P: 61 (8) 9248 4419
F: 61 (8) 9248 4901
APS: Singapore
Colombia
Chile
Perú
Brasil
Troubleshooting
Display cannot find or connect to the wireless sensor:
• Verify that DC power (9-33V) is applied to the sensor.
• Sensor may be out of range. Contact Preco Electronics for assistance.
“Not In Reverse” message is present, but machine is in reverse:
• Verify display and sensor are configured properly.
• For installation method A (see the display manual), verify reverse connection
has 9-33V present.
• For installation method B (see the display manual), verify sensor is powered
and communicating.
“Connection To Sensor Failed!” message is present:
• Verify display and sensor are configured properly (see the display manual).
• Verify sensor is powered and communicating (see the display manual).
There is a constant detection even if there is no object in the
machines vicinity:
• Check for any objects on the machine that the sensor may be detecting.
Relocate the sensor so it does not see these objects.
• If the detection is showing up in Zone 4 or 5, the sensor may be detecting the
ground. In an open field, either move the sensor up higher or slightly angle
the sensor upward 5 to 10 degrees. The minimum recommended mounting
height is 24 inches.