background image

COLLISION ALERT SYSTEMS

APS-SUPPLY.COM

www.aps-supply.com

APS USA

610 Gateway Center Way, Suites J & K

San Diego, CA 92102 USA

P: 1 619 263 4164

F: 1 619 263 6814

APS Australia

Unit 1, 72 Kent Way

Malaga WA 6090 Australia

P: 61 (8) 9248 4419

F: 61 (8) 9248 4901

APS:  Singapore

           Colombia

           Chile

           Perú

           Brasil

Troubleshooting

Display cannot find or connect to the wireless sensor:

•  Verify that DC power (9-33V) is applied to the sensor.
•  Sensor may be out of range. Contact Preco Electronics for assistance.

“Not In Reverse” message is present, but machine is in reverse:

•  Verify display and sensor are configured properly.
•  For installation method A (see the display manual), verify reverse connection 

has 9-33V present.

•  For installation method B (see the display manual), verify sensor is powered 

and communicating.

“Connection To Sensor Failed!” message is present:

•  Verify display and sensor are configured properly (see the display manual).
•  Verify sensor is powered and communicating (see the display manual).

There is a constant detection even if there is no object in the 

machines vicinity:

•  Check for any objects on the machine that the sensor may be detecting. 

Relocate the sensor so it does not see these objects.

•  If the detection is showing up in Zone 4 or 5, the sensor may be detecting the 

ground. In an open field, either move the sensor up higher or slightly angle 

the sensor upward 5 to 10 degrees. The minimum recommended mounting 

height is 24 inches.

Summary of Contents for Wireless PreView WorkSight WWS7220

Page 1: ...way Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 4901 APS Singapore Colombia Ch...

Page 2: ...e designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 3: ...4901 APS Singapore Colombia Chile Per Brasil CONTENTS Product Description Sensor Antenna Description Object Detection Capability Installation Instructions Before You Start Sensor Antenna Location Sen...

Page 4: ...ject detection system designed to alert vehicle operators to the presence of obstacles The system detects both moving and stationary objects in a pre defined coverage area and reports this information...

Page 5: ...ned signals to determine if an object has reflected any energy back to the sensor and reports this to the operator display The sensor is designed to process and report detections within of a second al...

Page 6: ...es an object reflects a certain amount of this energy back to the PreView sensor If the returned energy is of sufficient magnitude it is used to indicate object presence and determine the object s dis...

Page 7: ...APS USA 610 Gateway Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 4901 APS Singa...

Page 8: ...of the vehicle at roughly 36 1M 12 0 3M above the ground The sensor face should be perpendicular to the ground with the PreView graphic opening upward Select a location that will provide some protect...

Page 9: ...he display should be showing the Clear screen If the display is indicating a detection and there is no object in the machine s vicinity check for any objects on the machine which may be detected by th...

Page 10: ...System is intended for commercial use Proper installation of a back up aid requires a good understanding of truck electrical systems and procedures along with proficiency in the installation 7 Store...

Page 11: ...ion method A see the display manual verify reverse connection has 9 33V present For installation method B see the display manual verify sensor is powered and communicating Connection To Sensor Failed...

Page 12: ...Four 0 25 6 4mm diameter holes on 8 54 horizontal centers and 2 00 vertical centers Unit is supplied with 10 SS screws for mounting purposes Recommended torque is 22 inch lbs ELECTRICAL SPECIFICATION...

Page 13: ...S MANUFACTURERMAKESNOOTHERWARRANTIES EXPRESSED IMPLIED OR STATUTORY THE IMPLIED WARRANTIES FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUC...

Page 14: ...Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 4901 APS Singapore Colombia Chile Per Brasil PreView Configuration Options Custom System Configurations Thanks to th...

Page 15: ...supply com APS USA 610 Gateway Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 490...

Page 16: ...supply com APS USA 610 Gateway Center Way Suites J K San Diego CA 92102 USA P 1 619 263 4164 F 1 619 263 6814 APS Australia Unit 1 72 Kent Way Malaga WA 6090 Australia P 61 8 9248 4419 F 61 8 9248 490...

Reviews: