© 2017 Precision Lighting Ltd. We reserve the right to change details of design, materials and finish. Version 02.17
1. Installing the luminaire (Trimmed)
WARNING
switch off power to mains
before installation.
Cut ceiling hole at ø65mm (2 1/2 inch).
Note:
Due to small luminaire size
drivers must be located remotely; cut out
is too small for dimmable drivers to pass
through.
Pull driver side connector through
hole and connect to the luminaire side
connector. See electrical instructions for
wiring schematic. Compatible drivers
listed in front page table.
Using installation springs, install fixture
into the ceiling.
1. Installing the luminaire (Trimless)
WARNING
switch off power to mains
before installation.
Remove LED module from fitting.
Cut hole ø76mm (3 inches). Position
plaster-in ring and use appropriate
fixings to secure to ceiling.
Note:
Due to small luminaire size
drivers may need to be installed before
the trim is plastered in.
Trail mains cable through plaster in
ring. Apply plaster over plaster-in ring
and skim. Avoid covering wires and
connector with plaster. Cut around
inside of the aperature to ensure a neat
finish.
Once plaster is dry, connect driver to
luminaire.
Ensure the mains is switched OFF,
then connect the mains feed to the
driver.
Insert LED module into plaster-in ring
and add magnetic insert if required or if
removed during installation.
WARNING
Do not connect or disconnect under load.
Ensure driver has not been powered for a minimum of 1 minute before reconnecting the
LED module after disconnecting. Do not hot plug. Failure to follow this instruction will lead to
serious damage of the LED module and driver and will not be covered by warranty.
NOTE
LED module is not site serviceable.
Tampering will cause damage and will not
be covered by warranty.
NOTE
Maintain correct polarity when wiring. Incorrect wiring will cause serious damage and
will not be covered by warranty. Must be installed according to SELV regulations.
Wire specification: 22 AWG, ø0.65mm diameter double insulated teflon wire.
White - Positive
Black - Negative
1A.
1B.
MAINS
MAINS
For IP54 version the light
should first be installed without
the magnetic insert.
For IP54 version the light
should first be installed without
the magnetic insert.