background image

© 2017 Precision Lighting Ltd.    We reserve the right to change details of design, materials and finish.    Version   02.17

1. Installing the luminaire (Trimmed)

WARNING 

switch off power to mains 

before installation.

 

Cut ceiling hole at ø65mm (2 1/2 inch). 

Note: 

Due to small luminaire size 

drivers must be located remotely; cut out 
is too small for dimmable drivers to pass 
through.

 

Pull driver side connector through 

hole and connect to the luminaire side 

connector. See electrical instructions for 

wiring schematic. Compatible drivers 

listed in front page table. 

 

Using installation springs, install fixture 

into the ceiling. 

1. Installing the luminaire (Trimless)

WARNING 

switch off power to mains 

before installation.

 

Remove LED module from fitting. 

 

Cut hole ø76mm (3 inches). Position 

plaster-in ring and use appropriate 

fixings to secure to ceiling. 

Note: 

Due to small luminaire size 

drivers may need to be installed before 
the trim is plastered in.

Trail mains cable through plaster in 

ring. Apply plaster over plaster-in ring 

and skim. Avoid covering wires and 

connector with plaster. Cut around 

inside of the aperature to ensure a neat 

finish.

Once plaster is dry, connect driver to 

luminaire. 

Ensure the mains is switched OFF, 
then connect the mains feed to the 
driver. 

Insert LED module into plaster-in ring 

and add magnetic insert if required or if 

removed during installation.

WARNING

 Do not connect or disconnect under load.  

Ensure driver has not been powered for a minimum of 1 minute before reconnecting the 
LED module after disconnecting. Do not hot plug. Failure to follow this instruction will lead to 
serious damage of the LED module and driver and will not be covered by warranty.  

NOTE 

LED module is not site serviceable. 

Tampering will cause damage and will not 
be covered by warranty. 

NOTE 

Maintain correct polarity when wiring. Incorrect wiring will cause serious damage and 

will not be covered by warranty. Must be installed according to SELV regulations.  
Wire specification: 22 AWG, ø0.65mm diameter double insulated teflon wire.  
White - Positive 

Black - Negative

1A.

1B.

MAINS

MAINS

For IP54 version the light 

should first be installed without 

the magnetic insert.

For IP54 version the light 

should first be installed without 

the magnetic insert.

Reviews: