PD6928 Ex-Proof & I.S. Loop-Powered Flow Rate/Totalizer
Instruction Manual
62
Advanced Total and Grand Total Setup (
ADV TOTAL
&
ADV GTOTAL
)
The advanced total and grand total menu contain the count (
COUNT
) and reset (
RESET
) menus. The count menu
allows the digit limit to be selected between 8-digit (bottom display only) and 13-digit (uses top and bottom display to
display full number) and the initial value at which the total or grand total should start counting.
When using a 13-digit total or grand total, press the function key assigned to display (default: F1) to view the full
amount once the value has exceeded 100,000,000 (decimal places are automatically truncated). If a 13-digit total or
grand total is displayed on the bottom display and the value has exceeded eight digits, the truncated value will flash
to indicate that it is not the complete value. To display 13-digit grand total, assigned the top and bottom display to
grand total.
The reset menu is used to enable or disable the reset of the total and grand total.
Non-Resettable Grand Total
The grand total reset may be permanently disabled by selecting
YES
at the
PERMLOC
menu after disabling grand total
reset.
•
Use caution
when selecting the
PERMLOC
feature as once the grand total reset has been permanently locked, it
cannot be unlocked.