Model PD6363 Pulse Dual-Input Rate/Totalizer Instruction Manual
86
Display Description
Display Description
D gtot
Display grand total
Rst gb
Reset channel B
grand total
Big Hi
Max on big display
(Channel A)
Rst Hi
Reset max
Big Lo
Min on big display
(Channel A)
Rst Lo
Reset min
Big HL
Max/min big display
(Channel A)
menu
Menu button
Lit Hi
Max on little display
(Channel B)
Right
Right arrow button
Lit Lo
Min on little display
(Channel B)
up
Up arrow button
Lit HL
Max/min little display
(Channel B)
Enter
Enter button
Lit HC
Max on little display
(Channel C)
Alrm 1
Alarm 1 – 8 (Digital
Output)
Lit LC
Min on little display
(Channel C)
F on 1
Force on relay 1
LitHLC
Max/min little display
(Channel C)
F on 2
Force on relay 2
disabl
Disable function key
F on 3
Force on relay 3
up-d a
Total count mode
direction control,
channel A
F on 4
Force on relay 4
Meter Copy Function (
Copy
)
The
Copy
function is used to copy (or clone) all the settings from one
meter to other meters requiring exactly the same setup and
programming (
i.e
. type of input, scaling, decimal point, filter, bypass,
etc.).
Warning!
Only the PDA1200 meter copy cable must be used
for meter-to-meter interfacing.
Using standard CAT5 or other cable will cause
damage to both meters.
Copy Function Requirements
To successfully copy settings from one meter to another, both meters
must have the same software version and the same baud rate setting.
See
Determining Software Version
,
page 90 for instructions.