Function Keys & Digital Input
Available Settings
Refer to the following table for descriptions of each
available function key or digital input setting.
Display
Description
DISP FN
Set the function key or digital input to
display a value
DISPLAY
Cycle max, min, rate, total, and grand
total
D RATE
Display the rate
D TOTAL
Display the total
DISP GT
Display the grand total
PCT.RATE
Display the rate’s percentage of max
(20 mA)
D UNITS
Display rate, total, and grand total
units
D TAG
Display the tags
DISPMIN
Display the minimum rate value
DISPMAX
Display the maximum rate value
MIN MAX
Display the minimum and maximum
rate value
D mA IN
Display the current mA input value
D mAOUT
Display the current mA output value
MENU FN
Set the function key or digital input to
access a menu
RLYINFO
Go to relay information menu (
INFO
)
MANCTRL
Go to output control menu (
CONTROL
)
TIMR OC1
Open collector 1 timer
TIMR OC2
Open collector 2 timer
TIMER R1
Relay 1 timer
TIMER R2
Relay 2 timer
TIMER.FN
Set the function key or digital input to
start or stop a timer
STRT.ALL
Start all timers
STOP.ALL
Stop all timers
S.STP.ALL
Start or stop all timers
OC1
Start/stop open collector 1 timer
OC2
Start/stop open collector 2 timer
RLY1
Start/stop relay 1 timer
RLY2
Start/stop relay 2 timer
START
Start the selected timer output
STOP
Stop the selected timer output
STR-STP
Start or stop the selected timer output
BATCH.FN
Set the function key or digital input to
batch control
START
Start a batch
STOP
Stop a batch
STR-STP
Start or stop a batch
PRESET
Preset batch amount
ALARM.FN
Set the function key or digital input to
acknowledge an alarm
ACK
Acknowledge all active alarms
SETPOINT
Set all output set points
SETPT.OC1
Set open collector 1 set point
SETPT.OC2
Set open collector 2 set point
Display
Description
SETPT.R1
Set relay 1 set point
SETPT.R2
Set relay 2 set point
SWATCH.FN
Set the function key or digital input to
activate stopwatch
START
Start the stopwatch
STOP
Pause/Stop the stopwatch
STR-STP
Start or stop the stopwatch
HOLD FN
Set the function key or digital input to
hold an output
HOLD.OUT
Hold all outputs
HLD.UNHLD
Hold or un-hold all outputs
OC1+2
Hold/un-hold open collector outputs
RLY1+2
Hold/un-hold relay outputs
mAOUT
Hold/un-hold 4-20 mA output
HOLD
Hold selected output
HLD.UNHLD
Hold or un-hold selected output
DISABLE
Disable function key or digital input
RST FN
Set the function key or digital input to
reset a value
RESET
Reset min, max, or max/min rate value
R MIN.MAX
Reset max and min rate value
RST T
Reset the total
RST GT
Reset the grand total
RST T.GT
Reset the total and grand total