Diagnostics Menu (
diag
)
The
Diagnostics
menu is located in the
Advanced
Features
menu, to access
Diagnostics
menu see
. This menu
allows the user to test the functionality of all the
scanner LEDs, check the scanner
’s software and
version information, and erase the ScanView software
installation files from the scanner. Press the Enter
button to view the settings and the Menu button to exit
at any time.
Determining Software Version
To determine the software version of a scanner:
1. Go to the
Diagnostics
menu (
diAG
) and
press Enter button.
2. Press Up arrow button and scroll to
Information menu (
Info
).
3. Press Enter to access the software number
(
SFT
) and version (
UER
) information. Write
down the information as it is displayed.
Continue pressing Enter until all the
information is displayed.
4. The scanner returns to Run Mode after
displaying all the settings.
Reset Scanner to Factory Defaults
When the parameters have been changed in a way
that is difficult to determine what’s happening, it might
be better to start the setup process from the factory
defaults.
Instructions to load factory defaults:
1. Enter the
Advanced
Features
menu, see
2. Press Up arrow to go to
Diagnostics
menu
3. Press and hold Right arrow for three seconds,
press Enter when display flashes
reset
.
Note: If Enter is not pressed within three
seconds, the display returns to Run Mode
.
4. The scanner goes through an initialization
sequence (similar as on power-up), and loads the
factory default settings.
Testing the Display LEDs
To test all LEDs on the display:
1. Go to the
Diagnostics
menu (
diAG
) and
press Enter button.
2. Press Up arrow button and scroll to
LED Test
menu (
led t
)
3. Press the Enter button to activate the LED
Test. The scanner will cycle through all
digits, decimal points, and relay indicators to
enable the operator to check that all LEDs
are functioning properly.
4. Press the Enter button again to access the
Information
menu (
info
) or press the Menu
button to return to Run Mode.