19.2 Direct commands
Data in the direct commands are separated with a Tab (Hex 09) or semicolon (;). In setting or storing an
article all components of the article must always be transferred, even if not used. The numerical values may
only be transferred in grams, pieces or percentages. No other weight units will be accepted. 0 g must be
employed for unused numerical values. A hyphen may be used as a filler for alphanumeric values which are
not used.
19.2.1 Direct commands for the article
Place article in working memory
#SETA...
#SETA 111;1;TEST 111;12313-ASD;Roland Moor;0.25;g/PCS;800;PCS;750;PCS;850;PCS;25;g
Store article in memory
#STOA...
An article with the same article number will be overwritten.
If all article memory is full, subsequent articles will be ignored.
#STOA 111;1;TEST 111;12313-ASD;Roland Moor;0.25;g/PCS;800;PCS;750;PCS;850;PCS;25;g
#STOA 222;2;TEST 222;;;0.05;g/PCS;200;g;180;g;220;g;0;g
#STOA 333;3;TEST 333;12313-ASD;Roland Moor;0.1;g/PCS;3000;PCS;90;%;115;%;100;g
#STOA 444;4;TEST 444;123456-ABC;Roland Moor;0.02;g/PCS;0;g;0;g;0;g;20;g
Read an article
#GETA 111
Read all articles
#GETA ALL
The article will be
printed out in the same format, as stored with #STOA…
The data received can be stored in a text file and further processed using Excel.
Clear an article
#CLRA 111
Clear all articles
#CLRA ALL