Precisa 490 IB Series Operating Instructions Manual Download Page 3

Identification

   

1

En

gl

is

h

Identification

Customer service

Precisa Gravimetrics AG

Moosmattstrasse 32

CH-8953 Dietikon
Tel.

+41-44-744 28 28

Fax. +41-44-744 28 38

email

[email protected]

http://www.precisa.com

Refer to our website for information about local customer service centers and details of their addresses.

Copyright

These operating instructions are protected by copyright. All rights reserved. No part of the operating instructions may be reproduced, 
processed, duplicated or published in any form by photocopying, microfilming, reprinting or other process, in particular electronic 
means, without the written agreement of Precisa Gravimetrics AG.

© Precisa Gravimetrics AG, 8953 Dietikon, Switzerland, 2006.

Summary of Contents for 490 IB Series

Page 1: ...Precisa Balances Series 490 IB IT IS Operating Instructions 350 8114 000a3...

Page 2: ......

Page 3: ...cal customer service centers and details of their addresses Copyright These operating instructions are protected by copyright All rights reserved No part of the operating instructions may be reproduce...

Page 4: ...Prefix display 7 9 12 4b Control panel IT for text entry manual tara input reference input with preceding see also 9 2 23 9 3 24 12 Info display 4c Control panel IS for text entry working with the Sma...

Page 5: ...Place the weighing pan A in position Insert the power cable D into the socket at the rear of the balance 9 Components supplied Weighing pan A Balance B Operating instructions C Power cable D Warranty...

Page 6: ...3 Below balance weighing Objects which because of their size or shape cannot be put on the scale can be weighed by means of be low balance weighing The necessary parts are available as accessories se...

Page 7: ...t 10 V 10 V Resolution 10 mV 350 8508 Input Output module 6 TTL inputs 8 Relay outputs 350 8509 Signal lamp with 3 bulbs green yellow red 350 8510 Horn for signal lamp 350 8533 Multiplexer for up to 7...

Page 8: ...unctions 18 8 3 8 Date and time 18 8 3 9 Anti theft encoding 19 8 3 10 Key tone 20 8 3 11 Contrast 20 8 4 Special operating keys 20 8 4 1 The tare key 20 8 4 2 The print key 20 8 4 3 The change key 21...

Page 9: ...Contents 7 English...

Page 10: ...e for below balance weighing 5 1 Useful tips on the Operating Instructions You should read through these operating instructions in their entirety so that you can make optimum use of the full potential...

Page 11: ...ance and servicing The balance must not be operated in an area subject to explosion risks Take care when weighing liquids that no liquid is spilt into the inside of the balance or into connections on...

Page 12: ...ce with balances before you work with the balance and pay attention to the safety recommendations see chapter 6 Safety 7 2 Transport and shipping Your balance is a precision instrument Treat it with c...

Page 13: ...ion of the balance Since the Earth s gravity is not the same everywhere each balance must in accordance with the underlying physical weighing principle be adjusted to compensate for the gravity at eac...

Page 14: ...ce with the EC OIML provisions 7 10 Switching on the balance Press ON OFF to switch on the balance The balance carries out a diagnostic test in order to check the most important functions After comple...

Page 15: ...n menu 8 1 Menu control operation principle The configuration menu and the application menu each have several menu levels in which the parameters for the different function programs of the balance are...

Page 16: ...re printed in italics Keys type 1 Keys type 2 Designation Function in programming mode A B Changes within the menu level C D Up Down movements within the menu Changes selected parameters E Selects par...

Page 17: ...SPRACHE DEUTSCH LANGUAGE ENGLISH LANGUE FRANCAISE Selecting a language Display Key Step D Press repeatedly until the language currently activated is dis played sprache deutsch E The language now flas...

Page 18: ...ERFACE see chapter 8 3 7 Interface functions Display Key Step D Press repeatedly until UNIT 1 is displayed UNIT 1 9 E The unit now flashes unit 1 9 D Press repeatedly until the unit you require appear...

Page 19: ...ance location FLOATINGDISPLAY 0 32 SET CALIBRATION MODE OFF Closed EXTERNAL External EXT DEF External with user defined weight DEF n nnn g INTERNAL with internal weight AUTO Automatic AUTOCAL DEF 0 00...

Page 20: ...y key Put a weight on the balance Make a remote control command via the interface AUTO ZERO If the automatic zero correction AUTO ZERO is activated the balance always gives a stable zero e g even with...

Page 21: ...he anti theft encoding is deactivated in the factory settings The preprogrammed code set at the factory is 8 9 3 7 This code is the same in all balances Therefore for security reasons enter your own c...

Page 22: ...quence in accordance with the settings in the configuration menu see chapter 8 3 5 Calibration functions and reports these by means of a print out Activating an automatic repeatability test ART Ensure...

Page 23: ...lication menu and adapted to the user s needs The settings for the sub menus programmed in works are printed here in bold For greater clarity only that part of the menu tree which corresponds to this...

Page 24: ...cessary to define the chosen application program are shown in the SETUP APPLICATION menu SUM ANIMAL etc Add weighing results without intermediate tare Animal weighing Other functions available Refer t...

Page 25: ...stics functions if the statistics program is activ NOTE For basic operation Unit 1 is defined in the Configuration menu standard unit for all weighing procedures if the application program UNIT is not...

Page 26: ...000 9 F Press until COUNT appears Count 10 0000 9 C 25 is flashing the point of reference is measured 5 10 25 50 35 0000 9 C apply or remove e g 25 pieces 5 10 25 50 35 Pcs C The weight is recalculate...

Page 27: ...DISPLAY TEXT Unit shown in the display max 3 characters 10 0000 9 A SET is flashing The point of reference is measured set 30 0000 9 apply e g 20 0000g set 130 000 A The weight is recalculated in per...

Page 28: ...program you can add individual weighing results where the balance is tared to zero again before each individual weighing procedure Assignment of the function keys Display Key Step 13 4560 9 F Press u...

Page 29: ...sto 2 res inf Clear the measurements 0 0000 9 C Hold down the key until the acoustic signal sounds and the component counter is reset sto 2 res inf 0 0000 9 Measurements cleared balance is ready for...

Page 30: ...til the acoustic signal sounds and the component counter is reset sto 2 res inf 8 58962 9 Measurements cleared balance is ready for a new measurement sto 0 res inf A measurement log is printed by pres...

Page 31: ...DER Statistics program off Statistics only Data storage only Statistics and storage COUNT 100 Number of values to be stored automatically 1 500 RECORDING MANUAL TIMEBASE LOADCHANGE With STO i function...

Page 32: ...00 9 D Standard deviation STDe 0 00076 9 0 0000 9 D Relative standard deviation stde 0 02 0 0000 9 D Maximum max 3 4785 9 0 0000 9 D Minimum min 3 4770 9 0 0000 9 D Measurement 1 1 3 4770 9 0 0000 9 D...

Page 33: ...e display and II are active If II lights up the measured value lies within the specified tolerances SET CHECK CHECK MODE ON OFF NOM 100 000 g TO 120 000 g TU 80 000 g Switch application on off Enter n...

Page 34: ...eighing mode 12 2 Creating a new user profile If no user profile has yet been defined the balance can be used normally In order to work with different user configurations Work with Users must first be...

Page 35: ...started up the system asks for the desired user profile If one of the defined user profiles is selected the corresponding user password must be entered where necessary The user can then work with the...

Page 36: ...plex connection with additional hardware handshake in the peripheral device 12 V SB 1 2 3 4 5 6 7 8 SP 7 even 1 SB 1 DA 2 DA 3 DA 4 DA 5 DA 6 DA 7 DA PB SP 7 odd 1 SB 1 DA 2 DA 3 DA 4 DA 5 DA 6 DA 7 D...

Page 37: ...t 0 08 s n 2 t 0 16 s n 3 t 0 32 s N Reset balance OFF Switch off balance ON Switch on balance PCxxxx Enter anti theft code PDT Print out date and time PRT Start printing Press PRINT key PST Start pri...

Page 38: ...t x 1 4 of the balance with nn 0 g 1 mg 2 kg UxS Switch balance to unit x 1 4 ZERO Zero balance provided weight is stable and within the zero position range NOTE Each remote control command must termi...

Page 39: ...ove power adaptor plug from socket Also ensure that the balance cannot be reconnected to the power supply during the work by a third party Take care during cleaning that no liquid penetrates into the...

Page 40: ...for FLOATINGDISPLAY is too short The material being weighed is absorbing moisture The material being weighed is being blown away or is evaporating Strong temperature variations in the material being...

Page 41: ...see chapter 8 3 5 Calibration functions The balance now calibrates itself automatically every 24 hours and or after each temperature change of 3 degrees Celsius depending on the definition in the Con...

Page 42: ...en successfully installed you can start updating the balance software Balance software download Download the software for the balance from the website under Downloads and save it on your own PC Connec...

Page 43: ...14 Service 41 English Start the software update The software has been updated once the message Download successful appears...

Page 44: ...ANCE ID ON OFF PRODUCT ID ON OFF GROSS AND TARE ON OFF UNITS ON OFF USER ON OFF LINEFEED OFF 1 2 9 FORMFEED PRODUCT ttt PRODUCTMODE HOLD DELETE COUNT SET CALIBRATION MODE OFF EXTERNAL EXT DEF INTERNAL...

Page 45: ...N 1STOP 7 ODD 1STOP 7 NO 2STOP 8 NO 1STOP HANDSHAKE NO XON XOFF HARDWARE SET DATE AND TIME TIME HH MM SS DATE DD MM YY FORMAT STANDARD US THEFTCODE THEFTCODE THEFT PROTECTION OFF ON NEW CODE KEY TONE...

Page 46: ...ting Intructions for the description SETUP APPLICATION Division depends on the current application see chapter 8 5 Application menu SET STATISTIC MODE OFF STATISTIC RECORDER STAT RECORDER COUNT 100 RE...