3.
With console energized, press the E-STOP button on the console,
remote E-stop panel, or on any other device connected to the E-
STOP system. System should immediately stop and all power
should be removed from the console (except the purge-air circuit).
B.
Restarting after Emergency Shutdown
Before resetting the system, make sure that the system is back to safe
operating condition, and that the event causing the shutdown has been
identified and corrected.
1.
Twist and pull out all E-STOPS.
2.
Press the 3710 console E-STOP RESET button.
3.
If all E-STOPS are satisfied, E-STOP RESET button illuminates
and the purge sequence begins.
4.
If EMERGENCY STOP RESET doesn’t illuminate, check for an
E-STOP that has not been pulled out.
5.
Refer to the following subsections for normal operating
instructions.